Input Signal
Frequency Response
20 Hz to 20 kHz, ±0.5 dB
10 Hz to 80 kHz, ±3 dB
Distortion
<0.01% THD+N @ +4 dBu out
(page input <0.03%)
Dynamic Range
>110 dB unweighted (20 Hz–20 kHz)
(page input >100 dB)
Polarity
In-phase or reversed
Level Control Range
-95.5 to 0 dB in 0.5 dB steps
Precision Attenuator Transients
(“zipper noise”)
better than 112 dB below maximum output
Mute
>90 dB attenuation
Inputs
Program inputs
16
Paging input
1 Dedicated input with configurable
routing to any or all 16 input sections
Monitor bus input
1
Connector type
“Phoenix-style” (a.k.a. “Euro-style”)
detachable terminal blocks
Type Electronically
balanced
Grounding
All shield terminals connected
to chassis
Nominal level
1V/3V rms selectable (-10 dBV/+4 dBu)
Maximum level
+21 dBu
Impedance 25
k
Ω
balanced
Common-mode rejection
Typical, >50 dB, 20 Hz-20 kHz
Worst Case, >40 dB at 20 kHz
Crosstalk (inter-channel
within DataPort pair)
>75 dB separation (20 Hz–20 kHz)
Crosstalk (intra-channel
between DataPorts)
>90 dB separation, 20 Hz-20 kHz
measured with all inputs and
outputs terminated
Outputs
Program outputs
16 (via HD-15)
Connector type
8 HD-15 DataPort connections
Cable type
VGA monitor cable
1
Qualified length
2 meters
Monitor output
1
Connector
“Phoenix-style” (a.k.a. “Euro-style”)
detachable terminal blocks
Type Electronically
balanced
Grounding
Shield terminal connected to chassis
Nominal level
+4 dBu
Maximum level
+21 dBu
Output impedance
75
Ω
balanced
Output load
600
Ω
min
Power Amplifier Output Monitoring
Output Short Detect
*
Senses load <1
Ω
for Stereo/Parallel modes;
<2
Ω
Bridge Mono mode (default threshold)
Threshold is adjustable in software
Output Open Detect
*
Senses load >60
Ω
(default threshold)
Threshold is adjustable in software
Output Voltage Meter
Range automatically matches to
amplifier model used
Output Current Meter
Range automatically matches to
amplifier model used
Amplifier Headroom
Reports remaining available power
Amplifier Gain
*
Calculates and reports amplifier gain
(knob setting)
*Signal level must be higher than -32 dB, referenced to maximum output of amplifier
Power Amplifier Management
Power Amplifier Interface
Compatibility QSC
DataPort-equipped
amplifiers
Connector and cable
HD-15 VGA cable
1
, 2 meters length
2
qualified (for longer runs, contact QSC’s
Technical Services Department)
Amplifiers
Up to 16 channels (8 DataPorts) of
QSC DataPort-equipped amplifiers
Amplifier AC Power Control
AC mode control
Switches amplifier between operate
and standby mode
AC power indicator
Indicates operate, standby, or
power-down mode
Amplifier Status Monitor
Clip indicator
Senses channel clip status
Protect indicator
Senses amplifier protect status
Temperature meter
Reports amplifier operating temperature
Over-temp. alert
Software adjustable threshold (80°C default)
Control Room Foldback Monitoring
Number of Signal
Monitoring Buses per CM16a
1
Number of Channels per CM16a
4 (Maximum number assigned
to monitor mix at one time)
Internal Signal Monitor Points
(each with individual level controls)
Pre-fader input signal
16
Post-fader input signal
16
Power amplifier output
16
Monitor Input
Summed with internal monitor mix
at unity gain
Monitor in to monitor out
0 dB, ±1 dB
Nominal level
+4 dBu
Maximum level
+21 dBu
Input impedance
10k
Ω
balanced
Configuration
Active balanced, shield connected to chassis
Common-mode rejection
Worst case, >54 dB at 20 Hz rolling off to
>40 dB at 20 kHz
Typical case, >50 dB 20 Hz-20 kHz
Output
Sum of external monitor input and signals
from internal monitor mix
Frequency response
20 Hz–20 kHz, ± 0.5 dB
Distortion
<.05% THD @ +4 dBu out
Dynamic range
>90.5 dB unweighted, 22 Hz–22 kHz
Noise floor
-90.5 dB
Nominal level
+4 dBu
Maximum level
+21 dBu
Output impedance
75
Ω
balanced
Output load
600
Ω
min
Configuration
Active balanced
RS-232 Port
Cable Type
Null-Modem (a.k.a. Laplink), female 9-pin
D-sub chassis connector
Port Settings
Bits per Second
9600
Data Bits
8
Parity
none
Stop Bits
1
Flow Control
Xon/Xoff
Page Input
Specifications