background image

2

TD-001536-01-A

EXPLANATION OF SYMBOLS

The term “WARNING!” indicates instructions regarding personal safety. If the instructions are not followed the result may 
be bodily injury or death.

The term “CAUTION!” indicates instructions regarding possible damage to physical equipment. If these instructions are 
not followed, it may result in damage to the equipment that may not be covered under the warranty.

The term “IMPORTANT!” indicates instructions or information that are vital to the successful completion of the procedure.

The term “NOTE” is used to indicate additional useful information.

NOTE:

 

The intent of the lightning flash with arrowhead symbol in a triangle is to alert the user to the presence 

of un-insulated “dangerous” voltage within the product’s enclosure that may be of sufficient magnitude to 
constitute a risk of electric shock to humans. 

NOTE:

 

The intent of the exclamation point within an equilateral triangle is to alert the user to the presence of 

important safety, and operating and maintenance instructions in this manual.

IMPORTANT SAFETY INSTRUCTIONS

WARNING!:

 

TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT 

USE THIS APPARATUS NEAR WATER.

1.  Read these instructions.

2.  Keep these instructions.

3.  Heed all warnings.

4.  Follow all instructions.

5.  Do not use this apparatus near water.

6.  Clean only with a dry cloth.

7.  Do not block any ventilation opening. Install in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) 

that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one 

wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the 
third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for 
replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point 

where they exit from the apparatus.

11.  Only use attachments/accessories specified by the manufacturer.

12.  Unplug this apparatus during lightning storms or when unused for long periods of time.

13.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14.  The appliance coupler, or the AC Mains plug, is the AC mains disconnect device and shall remain readily operable 

after installation. 

Содержание KS212C

Страница 1: ...KS212C User Manual KS212C 3600 watt K Cardioid Sub TD 001536 01 A TD 001536 01...

Страница 2: ...l instructions 5 Do not use this apparatus near water 6 Clean only with a dry cloth 7 Do not block any ventilation opening Install in accordance with the manufacturer s instructions 8 Do not install n...

Страница 3: ...ry harm or related damages arising from any failure of the customer owner or user of the apparatus to facilitate those repairs Life Cycle 10 years Storage Temperature range 20 C to 70 C Relative Humid...

Страница 4: ...he concentration of the substance in all homogeneous materials of the part is below the relevant threshold speci ed in GB T 26572 X GB T 26572 X Indicates that the concentration of the substance in at...

Страница 5: ...vy duty casters 3 Ampli er protection rails protects the ampli er when the unit is rolled off for example a curb 4 M20 threaded socket for 35 mm speaker pole 5 Slip resistant feet four on the bottom 6...

Страница 6: ...ing woofers and through some clever use of spacing delay and polarity a cancellation of rear ring energy is created behind the subwoofer while also enhancing the forward ring energy The KS212C is powe...

Страница 7: ...do not place the unit closer than 50 mm 20 in from a wall or other object that would re ect sound waves Placement Make sure that the KS212C sub is placed no closer than 20 in 50 cm to the back wall of...

Страница 8: ...cal 16 Pole Yes Yes Yes Yes Yes Yes Yes No Vertical 26 Pole Yes Yes Yes Yes Yes No Yes No Vertical 36 Pole Yes Yes Yes Yes No No No No WARNING The KS212C Subwoofer is not intended or equipped for susp...

Страница 9: ...that can use input AC power voltages ranging from 100 240 VAC at 50 60 Hz WARNING Use only the power cable that is correct for your location Power Switch Push in on the top of the rocker switch to ap...

Страница 10: ...e KS212C 3 Turn off all audio source devices NOTE If a KS212C speaker is being driven from the output of another KS212C unit it should be turned on after the unit feeding it signal and turned off befo...

Страница 11: ...built in limiter is activated to protect and avoid damage to the ampli er or loudspeaker If the signal level at any frequency is too high or the ampli er is too hot the limiter is activated and the L...

Страница 12: ...menu item or change a selected parameter 5 Left side Home screen displays the parameter name 6 Right side Home screen displays the current state of the parameter Navigation Example To select a Preset...

Страница 13: ...When you save a scene all the current settings in the ampli er are saved to that scene Choose from User 1 through User 5 then press the enter button When saved a triangle displays next to the saved s...

Страница 14: ...14 TD 001536 01 A Dimensions Figure 16 33 4 in 847 5 mm 24 6 in 624 5 mm 15 3 in 389 mm 15 3 in 389 mm 15 3 in 389 mm 24 6 in 624 5 mm 24 6 in 624 5 mm Back View Front View 33 4 in 847 5 mm...

Страница 15: ...g XLR F inch Combo 2 x XLR M Loop Thru Output 1 x Locking IEC Power Connector AC Power Input Universal Power Supply 100 240 VAC 50 60 Hz AC Power Consumption 1 8th Power 100 VAC 3 6 A 120 VAC 3 0 A 24...

Страница 16: ...m Mailing Address QSC LLC 1675 MacArthur Boulevard Costa Mesa CA 92626 1468 USA Telephone Numbers Main Number 1 714 754 6175 Sales Marketing 1 714 957 7100 Toll free USA only 1 800 854 4079 Customer S...

Страница 17: ...QUICK START GUIDE KS212C...

Страница 18: ...PANEL IDENTIFIERS 5 1 10 2 3 7 4 9 8 6...

Страница 19: ...trombuchse verriegelbar 1 Af chage des menus et r glages 2 Appuyer pour quitter ou revenir en arri re 3 Tourner pour s lectionner un sous menu ou pour ajuster une valeur 4 Appuyer pour charger une val...

Страница 20: ...Monitor Right Left 4 3 2 1 USB Power Phones L R TouchMix 8 Aux 3 4 Cue Monitor Right Left 4 3 2 1 USB Power Phones L R TouchMix 8 SYSTEM HOOKUP Stereo Subwoofer and Tops THRU THRU IN IN THRU K8 2 K8 2...

Страница 21: ...en um einen einzustellenden Wert zu laden oder die Anzeige zu best tigen 3 Drehen um ein Untermen auszuw hlen oder einen Wert einzustellen 1 Appuyer pour quitter ou revenir en arri re 2 Appuyer pour c...

Страница 22: ...OOFER KS212C 2018 QSC LLC all rights reserved QSC the QSC logo and TouchMix are registered trademarks of QSC LLC in the U S Patent and Trademark other trademarks are the property of their respective o...

Страница 23: ...arrays through some clever manipulation of placement delay and polarity redirecting desired LF energy forward and minimizing energy at the sides and rear Unfortunately this technique is costly and re...

Страница 24: ...5 inches 622 x 394 x 851 mm Net Weight 40 1 kg 88 5 lbs Shipping Weight 48 5 kg 107 lbs Regulatory CE WEEE UL China RoHS RoHS II FCC Class B Included Accessories 4 x Low Noise Heavy Duty Casters 36 in...

Отзывы: