4
TD-000449-00-A
Presets
A preset confi gures the inputs and outputs, along with setting the DSP.
There are 20 Presets. See
Figure 9
.
From Home
ENTER
1. Previous selection
2. Currently selected
3. Next selection
4. Instructions
Recall a Preset
Recall a preset to confi gure the amplifi er to meet the requirements of your loudspeakers and installation.
There are 20 Presets. See
Figure 10
.
1. From Home
ENTER
2.
B
Preset,
ENTER
3.
B
Preset Recall,
ENTER
4.
B
the preset you want,
ENTER
ENTER
Save Preset
Saves the active preset with any DSP changes. See
Figure 11
.
1. From Home
ENTER
2.
B
Preset,
ENTER
3.
B
Preset Save,
ENTER
ENTER
Save Preset As
Select the Location and/or change the Name to save changes you make to the DSP.
See
Figure 12
and
Figure 13.
1. From Home
ENTER
2.
B
Preset,
ENTER
.
3.
B
Preset Save As,
ENTER
.
4.
B
Location
ENTER
5.
B
the Location (p1 to p20),
ENTER
.
6.
B
Name,
ENTER
.
7.
B
letter, number, hyphen, or space
ENTER
repeat. When fi nished
EXIT
.
8.
B
Save,
ENTER
ENTER
.
Stereo DSP (Digital Signal Processing)
The DSP is set for both channels equally, at the same time.
Any changes you make are made in real time – you hear the change as it is being made.
Sensitivity
See
Figure 15
through
Figure 17.
1. From Home
ENTER
2.
B
STEREO DSP,
ENTER
.
3.
B
Sensitivity,
ENTER
.
4.
B
1.2 V (+4 dBu) or 3.9 V (+14 dBu),
ENTER
.
— Figure 13 —
P1: ST SAT FULL RANGE
ENTER TO SELECT
1
2
STEREO DSP
PRESETS
UTILITIES
3
4
— Figure 14 —
PRESET > RECALL
ENTER TO SELECT
p20: MONO SUBS 100 HZ
2
ST
DSP
B
1
A
— Figure 15 —
P1: ST SAT FULL RANGE
ENTER TO SELECT
PRESET SAVE
PRESET RECALL
PRESET SAVE AS
— Figure 16 —
PRESET > SAVE AS
ENTER TO SELECT
P20: MONO SUBS 100 HZ
LOCATION
NAME
SAVE
— Figure 17 —
PRESET > SAVE AS
ENTER: PRESS TO ADVANCE
P20:
M
ONO SUBS 100 HZ
HOLD TO ACCEPT
— Figure 18 —
DSP > SENSITIVITY
SENSITIVITY: 3.9V (+14dBu)
SENSITIVITY: 3.9V (+14dBu)