background image

Section 3: 

Specifications

Frequency response

20 Hz–10 kHz ±0.3 dB (term. block inputs)

at 3dB below full

20 Hz–20 kHz ±0.7 dB (term. block inputs)

scale input voltage

20 Hz–20 kHz±0.2 dB (DataPort inputs)

Distortion

<0.01% THD+N @ +4 dBu out

Delay (throughput)

687.5 microseconds

Dynamic range

>93 dB unweighted
20 Hz–20 kHz, 1.5V, 4V and 9V sensitivity
>88dB unweighted
 20 Hz–20kHz, 18V sensitivity

Polarity

In-phase or inverted

Mute

>90 dB attenuation

Inputs

Program inputs

2

Connector type

“Phoenix-style” (a.k.a.
“Euro-style”) detachable  terminal blocks

Type

Electronically balanced

Grounding

All shield terminals connected to
chassis

Input sensitivity

1.5, 4.0, 9.0 or 18.0 Vrms

(full scale input level)

 6, 14.5, 21.5 or 27.5 dBu
3.5, 12.0, 19.0 or 25.0 dBv
Units are selectable in software interface

Impedance

8.3 K Ohm balanced
3.7 K Ohm unbalanced

Signal Processing 24 bit, 48 kHz.

Common-mode rejection

 >50 dB, 20 Hz–20 kHz

Crosstalk

>75 dB separation, 20 Hz–20 kHz

Outputs

Program outputs

2 (via HD-15)

Connector type

HD-15 DataPort connection

Pinout

Special, see appendix

Cable type

QSC DataPort cable

Qualified length

2 meters

Daisy-chain output

2 (1 per channel)

Connector

“Phoenix-style” (a.k.a.
“Euro-style”) detachable
terminal blocks

Type

Electronically balanced

Grounding

Shield terminal connected to
chassis

Output level

6.0 or 4.0 Vrms

(full scale)

18.0 or 14.5 dBu
15.5 or 12.0 dBv

Output impedance

600 Ohms balanced

27

Power amplifier connectivity

Power amplifier interface

Compatibility

all QSC and non- QSC amplifiers

Full-feature set

all QSC DataPort equipped amplifiers

Connector and cable

HD-15 VGA cable, 2 meters length
qualified (for longer runs, contact
QSC’s Technical Services Department)

RS-232 Port

Cable Type

9-pin serial cable, male-to-female

Maximum Length

25 feet (7.6 meters)

Contact closure input (sense)

Inputs

1 discrete input (pin #9 of RS-232 port)

Configuration

Single-ended input

Resistance for closure detect <150 Ohms
Resistance for open detect

>1.9 K Ohms

TTL Compatible
Maximum Voltage= +9vdc

Amplifiers

one 2-Ch. amplifier per DSP-3

Amplifier status monitor

Clip indicator

Senses channel clipping

Protect indicator

Senses amplifier protect status

(status monitoring not available for non-DataPort amplifiers)

Note: Specifications are subject to change without notice.

Содержание DSP-3'

Страница 1: ...DSP 3 Digital Signal Processor Amplifier Accessory Hardware Manual TD 000087 00 TD 000087 00 Rev D...

Страница 2: ......

Страница 3: ...1 Connecting to RS 232 Port 21 Daisy chaining the DSP 3 Outputs 22 Connection to Accessory External DC Power Supply 22 Applications Examples 23 Section 3 SIGNAL MANAGER SOFTWARE System Requirements 26...

Страница 4: ...l area is likely to causeharmfulinterference inwhichcase the user will be required to correct the interference at his or her own expense 4 SAFEGUARDS Electrical energy can perform many useful function...

Страница 5: ...hatprovides a solid physical mounting platform Connections include three D sub type connections a DB 9 connector acts as the RS 232 interface and an HD 15 through connector provides the DataPort inter...

Страница 6: ...controls That way you won t damageyourspeakersorcreateveryloudsoundsifyouapply a configuration that doesn t do what you thought it would As a general rule DO NOT CREATE SIGNAL LOOPS Do not mixtheoutp...

Страница 7: ...Mount the DSP 3 remotely and connect a QSC DataPort cable between the amplifier s DataPort and the DSP 3 s backside DataPort External power may be required for older models see top of page 2 Mount th...

Страница 8: ...fier The power supply must be plugged into an operational AC power receptacle Then plug the barrel connector coaxialpowerplug fullyintotheEXTERNALPOWERreceptacleontheDSP 3 When power is properly appli...

Страница 9: ...5 Using the Menu Bar see below at the top of the window choose the Help item and read the software help section The help system includes the contents of this hardware manual for paperless reference 6...

Страница 10: ...thing was connected and set up properly 7 ENSURE THE AMPLIFIER IS TURNED DOWN AND THAT YOU HAVE SUITABLE SPEAKERS CONNECTED FOR YOUR INTENDED CONFIGURATION For familiarization with the DSP 3 and the S...

Страница 11: ...re from the GAIN object right side to the OUT1 object The DRAW tool works by clicking on one of the nodes that you want to draw a wire between then while holding down the mouse button dragging the wir...

Страница 12: ...CH1OUTPUT CH2OUTPUT These terminal blockjacksprovidespost DSP processed signal from the DSP 3 for downstream devices ampli fiers monitoringbusses daisy chainingthepro cessed signal to a second amplif...

Страница 13: ...irectly mounted on a 2 RU QSC DataPortequippedamplifier thisconnectorplugs into the amplifier s DataPort connector Ifusedwith3 RUQSCDataPortequippedamplifi ers the DSP 3 will need to be remotely mount...

Страница 14: ...ywhere in signal chain High and Low Pass Shelf Filter Adjustable corner frequency Adjustable Q factor Adjustable gain Graphical response curve provided in software Ability to bypass all EQ with a sing...

Страница 15: ...Adjustable Gain Adjustable threshold Adjustable compression ratio Graphical response curve provided in software Assignable anywhere in the signal chain Signal Level Meter Peak or rms response Signal A...

Страница 16: ...Section 1 Introduction Block Diagram 16...

Страница 17: ...red for all other directly mounted to amplifiersituations When used with the Powerlight series of amplifiers or 3 RU 4 channel amps the DSP 3 requires use of the accessory external supply Theaccessory...

Страница 18: ...ght2 The DSP 3 mounts directly to the rear of 2 channel 2 RU DataPort equipped QSC amplifiers 1 Configure the amplifiers DIP switches QSC amplifiers where the DSP 3 covers the configuration switches a...

Страница 19: ...racket This accessory is a 19 2 RU panel with mounting facilities for up to four DSP 3 modules It is intended to be mounted to the rear support rails of an equipment rack The bracket kit comes with on...

Страница 20: ...t adjacent terminals Unbalanced inputs can be used if required If unbal anced audio sources are used it is preferable to use an appropriate audio transformer or other unbalanced to bal anced converter...

Страница 21: ...have to be maintained for the DSP 3 to operate Setup programming can also be done via Ethernet network communication when using QSC s QSControl products Refer to QSControl documentation for detailed i...

Страница 22: ...3fromanexternal power supply QSCoffersanaccessory externalpowersupplyforapplica tions where a DataPort that provides 15 VDC is not available Contact QSC s Technical Services Department for details Al...

Страница 23: ...d OR Local Control Audio Inputs via DataPort Thefollowingexamplesshowbasichookupinformationthatassumesatwo channel fullrangeaudiosignaldrivingtheload Refertoyour amplifier s hardware manual for other...

Страница 24: ...used with QSC DataPort Amplifier Audio Input via Terminal Block Inputs DSP 3 Directly Mounted to QSC Amplifiers Networked Control via QSCcontrol Products 24 NOTE External accessory power supply may be...

Страница 25: ...DSP 3 Remotely Mounted connected to any Non DataPort Amplifier Audio Input via Terminal Block Inputs Section 2 Installation Application Examples 25...

Страница 26: ...io signals to the inputs Damage to equipment may result if these recommendations are not followed The last applied configuration that is running in the DSP 3 when it is turned off becomes the active c...

Страница 27: ...l see appendix Cable type QSC DataPort cable Qualified length 2 meters Daisy chain output 2 1 per channel Connector Phoenix style a k a Euro style detachable terminal blocks Type Electronically balanc...

Страница 28: ...50 Celsius Accessory External Power Supply AC Input Voltage 80 240 VAC AC Input Current 0 3 Amps rms Frequency 50 to 60 Hz Output Voltage 15 VDC Output Current 300 milliamperes Output Termination Det...

Страница 29: ...compression ratio 29 Contact Closure I O The DSP shall provide a trigger input usableforcontact closure orother purposewhichshall be CMOS TTL signal compatible Power Supply The DSP shall be provided p...

Страница 30: ...not intended for inter face to other manufacturer s equipment 30 Note Powerlight 6 0 and Powerlight 9 0 amplifiers require that pin 9 be removed from the remote mounting interconnect cable Amplifier...

Страница 31: ...ain Relief Phoenix Contact 17 76 16 8 Phoenix Contact is the trademark of Phoenix Contact Inc Middletown PA Riacon is the trademark of RIA electronic Inc Eatontown NJ On Shore Technology is the tradem...

Страница 32: ...adequate power supply voltage to the module requiring the use of the same type of external DC supply as used with Powerlight amplifiers The amps in questionwillhaveaserialnumberPRIORto0899XXXXX where...

Страница 33: ...particularfilepathisassociatedwiththealgorithms now loaded in the DSP 3 When you connect a DSP 3 to a computer the Signal Manager software first attempts to locate and display the configuration file t...

Страница 34: ...Technical Services 714 957 7150 or 800 772 2834 toll free U S A only ADDRESS QSC Audio Products Inc 1675 MacArthur Boulevard Costa Mesa CA 92626 1468 USA Disclaimer QSC Audio Products Inc is not liabl...

Страница 35: ......

Страница 36: ...alifornia 92626 USA PH 714 754 6175 FAX 714 754 6174 Copyright 2001 QSC Audio Products Inc QSC is a registered trademark of QSC Audio Products Inc Costa Mesa CA QSC and the QSC logo are registered wit...

Отзывы: