Preliminary Specification

IN

OUT

THRU

Dynamic Range (AES-17, -60dB Method, all sensitivities)

unweighted

>115dB

>112dB

>110dB

A weighted

>118dB

>115dB

>113dB

Distortion (20Hz-20 KHz, all sensitivities)

+4dBu (max)

<0.009% THD+N

<0.009% THD+N

<0.009% THD+N

2dB below clip (max)

<0.009% THD+N

<0.009% THD+N

<0.009% THD+N

Crosstalk (20Hz - 20KHz)

inter-channel (max)

>75dB

inter-channel (typ)

>90dB

intra-channel (max)

>85dB

intra-channel (typ)

>100dB

Frequency Response

20Hz - 20KHz (max)

+/- 0.5dB

20Hz - 20KHz (typ)

+/- 0.2dB

Input Impedance

Balanced (nominal)

10K ohms

Unbalanced (nominal)

10K ohms

Common-Mode Rejection

20Hz - 20KHz (min)

>54dB

20Hz - 20KHz (typ)

>60dB

Input Sensitivities

Vrms: 1.5, 3, 9, 18

dBU: 5.7, 11.8, 21.3, 27.3

dBV: 3.5, 9.5, 19.1, 25.1

Audio Converters

24 bit, 48KHz, in and out

Mute

infinite attenuation

Delay

Analog input through full DSP chain to analog outputs

2.354 milliseconds (Default Group Delay)

Program Outputs

8

Connector Type

4 HD-15 dataport connections

Cable Type

QSC DataPort cable, QSC p-n DPC-x (“x” designates cable length in feet)

Available “stock” Lengths

1, 2, 3, 4, 5, 6, 10, and 20 ft., custom lengths available.

Maximum Qualified Length

32.8 ft. (10 m)

Program Inputs

8

Connector Type

3-pin "Phoenix Style" (a.k.a. "Euro Style") detachable terminal blocks

Type

Electrically balanced

Grounding

All shield terminals connected to chassis

Pinout

1:+  2:-  3:CHASSIS GND

Specifications are subject to change without notice.

Содержание BASIS 722az

Страница 1: ...TD 000145 00 rev A TD 000145 00 BASIS 722az 8x8 Control and Monitoring Signal Processor Hardware Manual...

Страница 2: ...cord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE...

Страница 3: ...tablets etc all at the same time from anywhere a connection to the QSControl network is available The QSControl network can also be managed from a single computer running both the client and the serv...

Страница 4: ...g so will ensure a network with predictable behavior and one that offers the highest level of confidence and long term reliability Second the BASIS 722az and QSControl net system are targeted at netwo...

Страница 5: ...monitor your BASIS 722az BASIS 722az QSControl Port NIC CAT 5 Crossover Cable QSControl net Example 2 Unmanaged Switch This example illustrates an unmanaged Ethernet network An unmanaged switch is use...

Страница 6: ...affic The partitioning provides a dedicated virtual local area network VLAN for the BASIS 722az and all other QSControl devices including a management PC running the QSControl net server or client app...

Страница 7: ...or out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack M...

Страница 8: ...Windows 2 If there are any programs running please close them now Be sure to leave Windows running 3 Place the QSControl net CD ROM in your CD ROM drive If your system supports the Auto Run feature i...

Страница 9: ...on off or state change events the variable resistor input provides full 8 bit resolution allowing for incremental change events Refer to the illustrations for connection recommendations NOTE 48 volts...

Страница 10: ...io and amplifier status monitoring This can be four 2 channel amplifiers or one 8 chan nel amplifier or other suitable combinations If connecting a multi DataPort amplifier ensure all the DataPorts of...

Страница 11: ...her side of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accep...

Страница 12: ...lt Boot Screen Right side buttons serve as up down navigation Arrow characters indi cate right side button context If additional menus are available the arrow character will be shown Main Menu Screens...

Страница 13: ...Client Server selection keep both Client and Server selected This will be appropriate for general use 8 When prompted Select Installation Folder specify the installation directory or accept the defaul...

Страница 14: ...nections verify IP addresses are set correctly ver ify Subnet masks are set correctly and verify AC power is properly applied to the BASIS 19 Click on the BASIS 722az in the inventory root A view of a...

Страница 15: ...imited TCP IP communications with the BASIS 722az Once communication has been re estab lished the file transfer can be tried again or the old application file used until the source of the data transfe...

Страница 16: ...ick OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter h...

Страница 17: ...opening a Telnet session 1 To open the Telnet session Click Start select Run type Telnet followed by a space then the IP address of the BASIS 722az you want to communicate with in the text box and cli...

Страница 18: ...4dB 20Hz 20KHz typ 60dB Input Sensitivities Vrms 1 5 3 9 18 dBU 5 7 11 8 21 3 27 3 dBV 3 5 9 5 19 1 25 1 Audio Converters 24 bit 48KHz in and out Mute infinite attenuation Delay Analog input through f...

Страница 19: ...nical Relay Pinout 1 NC 2 NO 3 COM Switching Capacity nom 1A 30VDC Logic Outputs 4 discrete outputs Connector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single...

Страница 20: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Отзывы: