QSC AD-C42T Скачать руководство пользователя страница 5

Installation Procedure

1-

 Using the included C-ring or the dimensions provided, trace a cutout pattern onto the 

ceiling surface.

2-

 Cut the mounting hole. Use a sharp tool to avoid stressing or cracking the mounting sur-

face.

3- 

Pull the wires through the hole.

4

- Pass the two suspended ceiling support brackets through the hole and place as shown 

in the illustration. Make sure the part of the bracket that is flat against the tile is toward 
the hole. If installing in a non-suspended ceiling application, these brackets are not 
required.

5-

 Pass the C-ring bracket through the hole. Slide the cutout slot into the hole first, and 

then rotate the bracket so it passes through the hole. Be sure the wires pass through the 
ring.

6-

 Position the support brackets, and secure the C-ring bracket to each of the support 

brackets using the screws provided. If installing in a non-suspended ceiling application, 
skip this step.

7-

 Loosen the connection cover plate retaining screw and swing the cover open. Install an 

fitting into the hole provided on the cover plate.

8- 

Temporarily support the enclosure so the wires may be passed through the enclosure 

top with enough slack to prepare and terminate the wires. 

9- 

Locate the terminal block connectors included with the loudspeaker. Loosen the wire 

retaining screws fully.

10- 

Strip the wire ends approximately 10 mm (0.4”) and insert each wire into its proper 

connector position. Tighten the wire retaining screws fully.

11- 

Rotate the connection cover plate closed, making sure not to stress the connections or 

pinch the wires. Tighten the cover plate’s retaining screw.

12-

 Adjust the wiring at the entry  point, if necessary, and properly secure fitting. This pre-

vents wire stress and strain from pulling the connections/connectors loose.

13-

 Attach a safety cable (secondary support cable) from the enclosure’s attachment tab to 

an appropriate support point. This cable and the attachment points must be strong enough 
to support many times the weight of the loudspeaker in the event the primary mounting 
system fails.

14-

 Insert the enclosure into the ceiling cutout, making sure any brackets used remain 

properly positioned. Tighten the loudspeaker’s mounting clamp screws.

15-

 Set the tap selector switch to the desired position. 70V systems, all four positions may 

be used. Do not use highest tap setting with 100V systems. 8 ohm systems, selector to 8 
ohm position.

16-

  Make sure all tests and adjustments are complete before installing the grills. Locate 

the loudspeaker’s grill. The cabinet and the grill both have a small loop of plastic line. 
Using the clip on the grill’s line, attach the grill’s safety loop to the cabinet’s loop. Carefully 
work the grill into its retaining slot and press firmly into place. Work the grill in slowly and 
evenly to avoid damage. Make sure all tests and adjustments are complete before install-
ing the grills.

Get other manuals https://www.bkmanuals.com

Содержание AD-C42T

Страница 1: ...TD 000263 00 TD 000263 00 A AcousticDesignTM In ceiling Loudspeakers User Manual AD C42T 105 mm 4 two way Get other manuals https www bkmanuals com...

Страница 2: ...ts Inc QSC is a registered trademark of QSC Audio Products Inc QSC and the QSC logo are registered with the U S Patent and Trademark Office All trademarks are the property of their respective owners W...

Страница 3: ...ion professional be consulted for safety assurance quality installation and optimum acoustic performance For suspended ceiling applications the suspended ceiling support brackets must be used with the...

Страница 4: ...ht The clamp rotates 90 and is then pulled tight by the screw see 3 right Grill Safety Clip The cabinet and the grill both have a small loop of plastic line The grill s loop has a clip attached Using...

Страница 5: ...d insert each wire into its proper connector position Tighten the wire retaining screws fully 11 Rotate the connection cover plate closed making sure not to stress the connections or pinch the wires T...

Страница 6: ...d tighten Suspended ceiling C ring and support bars included Connectors Ceramic block connector inputs and terminal block through connectors rated for 400W max Controls Transformer tap selector bypass...

Страница 7: ...AD C42T Dimensions CUTOUT HOLE DIAMETER 191 mm 7 50 USE C RING FOR TEMPLATE MATERIAL THICKNESS RANGE FOR CLAMP MOUNTING 5 6 19 0 mm 0 22 0 75 Get other manuals https www bkmanuals com...

Страница 8: ...eting 714 957 7100 or toll free USA only 800 854 4079 Customer Service 714 957 7150 or toll free USA only 800 772 2834 Facsimile Numbers Sales Marketing FAX 714 754 6174 Customer Service FAX 714 754 6...

Отзывы: