14.1.3.
Diagnostic Steps
The diagnostic steps are listed below:
If disk drive errors in the event logs are occurring, we suggest replacing a healthy one.
For more information, please refer to the chapter 14.2,
If the fault is occurring from volume configuration. For example, the pool or volume
configuration is deleted by accident. Please refer to the chapter 14.3,
section for disaster recovery.
If the fault is occurring from other hardware components of the system, the faulty
component will need to be replaced.
14.2.
Rebuild
If any single disk drive of the storage pool in protection RAID level (e.g., RAID 1, 3, 5, 6, 0+1,
10, 30, 50, and 60) fails or has been removed, then the status of pool will be changed to
degraded mode. At the same time, the system will search the spare disk to execute volume
rebuild the degraded pool into complete one.
There are three types of spare disk drive which can be set in function menu
Disks
:
Dedicated Spare
: Set a spare disk drive to a dedicated pool.
Local Spare
: Set a spare disk drive to the pools which located in the same enclosure.
The enclosure is either in head unit or in one of expansion units.
Global Spare
: Set a spare disk drive to all pools which located whether in head unit and
expansion unit.
The detection sequence is the dedicated spare disk as the rebuild disk first, then local spare
disk and global spare disk.
The following examples are scenarios for a RAID 6 rebuild.
1.
When there is no global spare disk or dedicated spare disk in the system, the pool will be
in degraded mode and wait until there is one disk assigned as spare disk, or the failed
disk is removed and replaced with new clean disk, and then the Auto-Rebuild starts.
2.
When there are spare disks for the degraded array, system starts Auto-Rebuild
immediately. In RAID 6, if there is another disk failure occurs during rebuilding, system
will start the above Auto-Rebuild process as well. Auto-Rebuild feature only works at
that the status of pool is
Online
. Thus, it will not conflict with the online roaming feature.
Содержание XCubeSAN XS5224D
Страница 71: ...SANOS User Interface 49 nnnnn RPM Power Supply Local PSU n status Reset to Default Yes No...
Страница 99: ...System Settings 77 Figure 6 14 System Information...
Страница 315: ...Monitoring 293 Figure 13 5 Hardware Monitoring...
Страница 327: ...Support and Other Resources 305 Figure 15 1 Download Service Package in the SANOS UI...
Страница 331: ...Support and Other Resources 309...