Figure 6-17
Example of a Failed Port on the 10GbE iSCSI Host Card
The following content and images are detailed steps of removing a host card from the
system.
Remove the controller module first. For detailed steps
of removing a controller module;
please refer to the chapter 6.1,
Removing / Installing the Controller Module
Press the host card release button and disconnect the host card with the connector in
the controller cage.
Pull the host card out until it is free from the controller cage.
Install the substitute host card. The detailed steps of installing a host card; please refer
to the chapter 3.3,
Installing the Optional Host Cards
Install the dummy host card cage in the empty host card slot and tighten two screws.
Repeat the procedures above if there are other host cards need to be removed.
To ensure the system cooling, please install all dummy host adapter card cages if host
cards are removed.
Figure 6-18
Procedures of Removing the Host Card from the Controller Cage