Figure 2-10 Mechanical Components of the Fan Module
Table 2-10 Mechanical Components of the Fan Module
ITEM NUMBER
DESCRIPTION
1
Fan Module Release Tab
2
Fan Module Handle
2.5.
Cache-to-Flash Memory Protection
In the event of power loss, the I/O cache data stored in the volatile memory will be lost; this
can cause data inconsistency especially in database applications. The system can provide an
optional Cache-to-Flash memory protection function that will safely transfer the memory cache
data to a non-volatile flash device for permanent preservation. The Cache-to-Flash module
comes with an M.2 flash module and a BBM (Battery Backup Module). All modules are hot
pluggable with zero system downtime for extra availability and reliability. M.2 flash module can
be plugged in on the left hand side from the rear of the chassis. Power module can be plugged
in on the right hand side from the rear of the chassis. Images and tables below illustrate the
location and mechanical components of the cache-to-flash modules. Please refer to the chapter
4.5,
Removing / Installing Cache-to-Flash Module
to maintain the Cache-to-Flash module.