QRO Technologies HF-3KDX Скачать руководство пользователя страница 12

 

12

 

Place your transceiver in the CW mode or any mode that will provide a continuous carrier for tune-
up. 

At this time make sure that your transceivers output power level has been set to zero.

  

 

TUNE UP PROCEDURE

 

 

Before  making  any  tune  up  procedures,  make  sure  your  amplifier  is  connected  to  an 
appropriate load capable of handing at least 1,500 watts of power. Failure to do so may 
result is serious damage to your amplifier. 

 

 
When the three minute warm-up cycle has been completed, the red power light will turn on. The 
amplifier is now ready for tune up. At this point, place your transceiver in the SSB mode with the 
microphone gain at zero. Put the amplifier's Operate/Standby switch in the operate position. Key 
your transceiver and you should notice the green transmit LED on the amplifier lite. You should 
also hear  the amplifier's internal relays latch. With the transceiver keyed and the amplifier's Multi-
meter  switch  in  the  PC  position,  observe  the  plate  current  (PC). 

It  should  be  in  the 

neighborhood of .200 amperes more or less

. Un-key your transceiver, and place the amplifier 

in the standby mode.  
 

TUNEUP  OBJECTIVE:

  The  objective  of  the  tune-up  procedure  is  to  bring  the  amplifier  to 

resonance by adjusting the tune & load controls desired maximum output power.  
 
1. Place your transceiver in CW mode, and set its output power level to 60 watts. 
 
2. 

Select your desired band using the amplifier’s bandswitch. 

 
3. Put the Multi-meter switch in the PC position.  
 
4. Place the amplifier in the operate position. 
 
5. Set the Tune Control to 0. 

 

6. Set the Load Control to 50 for 160 thru 40 meters. Set the Load Control to 30 for 20 thru  
    10 meters. 
 
7. Key your transceiver and advance the Tune Control clockwise looking for a dip in the plate 
current. Note: If the amplifier faults rotate the load control counterclockwise, and reset the Fault 
Switch. If the amplifier still faults, turn to load control counterclockwise some more.  
 
8. Continue advancing the Tune Control clockwise until the dip in plate current reverses and starts 
to rise. 
 
9. Adjust the Loading Control for maximum output power. 
 
10. Redip the plate current using the Tune Control and readjust for maximum power using the 
Load Control. Repeat this step as needed.  
 
The amplifier should now be tuned for maximum output power with 60 watts of input power. If you 
desire lower or higher output power decrease or increase input power and retune for maximum 
desired output power. 

Содержание HF-3KDX

Страница 1: ...an OH 43506 USA Tel or Text 419 551 9354 E mail kb8vu qrotec com Internet http www qrotec com PUBLICATION DATE September 2012 COPYRIGHT 2012 BY QRO TECHNOLOGIES INC ALL RIGHTS RESERVED THIS MANUAL OR ANY PART THERE OF MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION FROM QRO TECHNOLOGIES INC ...

Страница 2: ... negative going adjustable from Front Panel Harmonic Suppression Meets F C C Requirements Keying Requires relay contact closure or sink of 80 ma 12 VDC or 15 VDC on transmit supplied by transceiver Input Impedance 50 ohms unbalanced VSWR 1 5 1 Output Impedance 50 ohms unbalanced with SWR 2 1 or less Tube Requirement 1 8877 3CX1500 Triode Power Line Requirement 220 240 VAC 60 Hz at 25 amperes maxim...

Страница 3: ...ion 7 Location 7 AC Power Line Considerations 7 8 Antenna 8 Grounding 8 Equipment Interconnections 9 Safety Interlock Switch 9 Driving Power 9 10 Tube Precaution 10 Reading the Meters 10 Front Panel Switches Controls 10 11 Initial Power Up 11 Tune Up Procedure 12 13 Using the ALC Adjust Control 14 Periodic Maintenance 14 Troubleshooting Chart 14 15 Schematics PCB Layouts Parts Lists 16 ...

Страница 4: ...the buyer Please call the factory at 1 419 551 9354 for shipping instructions Make sure when returning the amplifier you have insured the instrument for the full replacement cost QRO Technologies Inc is not liable for any damage incurred during return shipments PROPRIETARY NOTICE _____________________________________ This instruction manual schematic diagrams printed circuit board layouts and tech...

Страница 5: ...nected to the neutral earth pole of the power supply Before operating this unit ensure that the protection conductor green wire is connected to the ground earth protective conductor of the power outlet Do not defeat the protective features of the third protective conductor in the power cord by using a two conductor extension cord or a three prong two prong adapter Before operating this unit 1 Ensu...

Страница 6: ...ALLATION Before performing any of the following installation procedures make sure that the amplifier has not been plugged into the AC supply line As part of the installation process you must install the tube and transformer PLATE TRANSFORMER Remove the plate transformer from its shipping carton You will notice two indexed connectors Position the transformer so the connector with the red leads is o...

Страница 7: ...ace the amplifier in the transmit mode LOCATION Do not operate the Amplifier in excessively warm locations or near heating vents or radiators Be sure air can circulate freely around and through the Amplifier cabinet and can provide an unobstructed air inlet for the internal cooling fan Do not place any books magazines manuals or equipment that will impede the free flow of air near the sides and th...

Страница 8: ...n mind that the green line cord wire is connected to the Amplifier chassis ANTENNA The output circuit of the Amplifier is designed to be connected to an unbalanced transmission line that has a 50 ohm characteristic impedance Lines of other characteristic impedance may be used providing the SWR standing wave ratio does not exceed 2 1 The RF OUT connector is a UHF type SO 239 You will need a mating ...

Страница 9: ...perate Standby switch located on the front panel ALC OUTPUT Connect this socket to the ALC input of your transceiver A 0 to 20 V negative ALC voltage is present at this socket Refer to your transceiver manual for proper connection information Whenever the Amplifier is overdriven the ALC circuitry creates a negative voltage that is fed back to the transceiver to reduce its gain and help prevent fla...

Страница 10: ...tage Bottom scale indicates 0 to 7 0 KV normal operating range is 3 0 4 0 KV volts Each division represents 2 KV 200 volts Plate Current PC Plate Current Top meter scale indicates 0 to 1 4 amperes Each division represents 4 amperes 400 milliamperes Grid Current Meter The left hand meter always indicates grid current between 0 and 300 milliamperes Each Division indicates 10 milliamperes FRONT PANEL...

Страница 11: ... Switch Selects the desired band of operation Red LED When lit the amplifier has been turned on and it has gone through its warm up cycle Green LED When lit the amplifier has been keyed and amplifying the power supplied by the transceiver INITIAL POWER UP Preset the amplifier s front panel controls as follows On Off Off Operate Standby Standby Multi meter PV Plate Voltage Fan Fan High ALC Adjust F...

Страница 12: ...EUP OBJECTIVE The objective of the tune up procedure is to bring the amplifier to resonance by adjusting the tune load controls desired maximum output power 1 Place your transceiver in CW mode and set its output power level to 60 watts 2 Select your desired band using the amplifier s bandswitch 3 Put the Multi meter switch in the PC position 4 Place the amplifier in the operate position 5 Set the ...

Страница 13: ...3 60 3 90 7 20 14 20 21 30 28 50 WARC BAND OPERATION The HF 3KDX has not been designed to operate on the WARC Bands This occurs because there are not enough bandswitch positions to accommodate these bands You can get some amplification on 17 12 meters You will have to use your transceiver s internal antenna tuner This will get you a proper input match to the amplifier Also you will have to set the...

Страница 14: ...e blades of the blower Any large accumulation of dust on the blades will impede proper cooling air to the tube TROUBLESHOOTING CHART The following charts lists specific difficulties that could occur in your Linear Amplifier Several possible causes may be listed for each difficulty Refer to the Printed Circuit Board diagrams PCB and the Schematic Diagrams to locate and identify the parts listed in ...

Страница 15: ...nents on LV Bias PCB a Fuse F301 F302 b Bridge Rectifier D301 c Reg 301 2 Meter Lamps PL1 PL4 Meter Switch Amplifier will not key when transceiver is keyed to transmit 1 Components on LV Bias PCB a Fuse F301 F304 b Bridge Rectifier D303 2 Operate Standby SW5 Front Panel ALC Inoperative 1 Improper connection between transceiver and amplifier 2 POT R13 ALC Adjust on front panel No RF Output 1 Improp...

Страница 16: ...16 SCHEMATICS PCB LAYOUTS PARTS LISTS Schematic diagrams printed circuit board layouts and parts lists can be downloaded from our website qrotec com ...

Страница 17: ...17 ...

Отзывы: