DO NOT touch or move gas appliance
for at least 45 minutes after use. 
Allow all burner elements to cool 
before touching.

FOR YOUR SAFETY ;

WARNING:

NOTE:

In a salt-air environment such as 
near an ocean, corrosion occurs 
more quickly than normal. 
Frequently check for corroded 
areas and repair them promptly.

NOTE:

Wait until gas appliance is cool before 
covering.

CLEANING AND MAINTENANCE : 

To enjoy years of outstanding performance from your 
gas fire pit, make sure you perform the following
maintenance activities on a regular basis:

Keep exterior surfaces clean.

Use warm soapy water for cleaning. Never use
flammable of corrosive cleaning agents.

While washing your unit, be sure to keep the area
around the burner dry at all times. If the gas control is 
exposed to water in any way, do NOT try to use it. It
must be replaced.

Keep the appliance area free and clean from combustible

Check if there are cracks or worn sections on the hose. If 
yes, please call our customer service to replace hose.

materials, gasoline and other flammable vapors and 
liquids; not obstructing the flow of combustion and
ventilation air; keeping the ventilation opening(s) of the 
cylinder enclosure free and clear from debris.

Gas fire pit does NOT reach the desired temperature.
Gas fire pit glow is excessively uneven.
Gas fire pit makes popping noises.

At least once a year, the unit should be inspected

 for 

the presence of spiders, spider webs or other insects.

Air flow must be unobstructed. Keep controls, burner,
and circulating air passageways clean. Signs of possible
blockage include:

Spiders and insects can nest in burner or orifices.

 

This

 

dangerous condition can damage gas fire pit and

 

render it 

unsafe for use. Clean burner holes by using a heavy-duty

 

pipe cleaner. Compressed air may help clear away

 

smaller 

particles.

MAINTENANCE AND STORAGE 

18

Содержание GFP02T

Страница 1: ...28 SRGF11626 GFP02T ...

Страница 2: ... are enforced Do not try to light the appliance Do not touch any electrical switch do not use any phone in the vicinity of this product Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING CARBON MONOXIDE HAZARD Improper installation adjustment alteration service or maintenance can c...

Страница 3: ...be required as necessary It is imperative that control compartment burners and circulating air passageways of the appliance be kept clean Alert children and adults to the hazards of high surface temperatures and keep them away to avoid burns or clothing ignition Carefully supervise children and pets when they are near the appliance Replace guard or other protective device removed for servicing Do ...

Страница 4: ... to assemble fire pit Call the toll free number on the cover page for replacement parts Leave hardware installed HALF TIGHTENED on the gas fire pit during assembly until unit is completely assembled then finish tightening all hardware installed YOUR OWNER S MANUAL Keep and store this Owner s Manual for future reference it contains important instructions and procedures for safety and maintenance NO...

Страница 5: ...4 TOOLS NEEDED NOT INCLUDED Screwdriver Estimated time for assembly 30 45 minutes PACKAGE CONTENTS G L N A D D H I K J F C D M E B ...

Страница 6: ... A 1 B 2 C 3 D E F G H I J K L M N 1 2 1 1 1 1 Gas Valve Panel Door Door Handle Cylinder Holder Cylinder Locking Bolt Cover Lid Protecting Wire Lava Rock 1 1 PACKAGE CONTENTS HARDWARE CONTENTS shown actual size M5 x 12 Bolt Assembly M5 x 12 Bolt M5 x 20 Bolt M6 x 12 Bolt ST4 2 x 9 5 Bolt Qty 4 Qty 20 Qty Qty 16 Qty 4 4 AA CC DD EE BB 1 1 ...

Страница 7: ... fire pit finish and assembly area Attach 3 legs D and 1 leg with door magnet E to the table top A with 12 M6x12 bolts DD as Fig 1 Attach side panel A B to leg with door magnet E and leg D with 2 M5x12 bolts BB as Fig 2 Hardware Used DD M6 x 12 Bolt x 12 Hardware Used BB M5 x 12 Bolt x 2 Fig 1 Fig 2 ASSEMBLY INSTRUCTIONS 44 4 44 4 ...

Страница 8: ... bolts assembly AA Insert valve into the injection pipe of burner as illustrated Insert the end of electrode wire into valve as illustrated Fully attach the side panel A B to the legs D E with 4 M5x12 bolts BB as Fig 4 Hardware Used BB M5 x 12 Bolt x 4 Hardware Used AA M5 x 12 Bolt Assembly x 4 Fig 3 Fig 4 G ...

Страница 9: ...RUCTIONS Attach side panel B2 C to legs D with 6 M5x12 bolts BB as Fig 6 Hardware Used BB M5 x 12 Bolt x 6 Hardware Used BB M5 x 12 Bolt x 6 Attach side panel B1 C to legs D with 6 M5x12 bolts BB as Fig 5 Fig 6 Fig 5 ...

Страница 10: ... to cylinder holder J as Fig 7 K DD Hardware Used DD M6 x 12 Bolt x 4 Fig 7 Cylinder Holder Assembly Attach the cylinder holder assembly to 4 legs with 4 M5x20 bolts CC as Fig 8 Note Make sure the cylinder locking bolt K plastic head is facing outwards Fig 8 Hardware Used CC M5 x 20 Bolt x 4 J ASSEMBLY INSTRUCTIONS ...

Страница 11: ...10 hot fire bowl as Fig 9 H I Fire Bowl Hardware Used BB M5 x 12 Bolt x 2 Fig 9 Screw door handle I to door H as Fig 10 Fig 10 ASSEMBLY INSTRUCTIONS ...

Страница 12: ...t right leg D assembly with 4 ST4 2x9 5 bolts EE as Fig 11 Note With the help of a friend turn the gas fire pit into upright position after this step finished Hardware Used EE ST4 2 x 9 5 Bolt x 4 Fig 11 ASSEMBLY INSTRUCTIONS ...

Страница 13: ...e burning area of the table top A Place the cover lid L onto the table top A when the gas fire pit is not in use Note to avoid ignition failure do not cover the flame orifice with lava rocks Flame Orifice Fig 12 ASSEMBLY INSTRUCTIONS ...

Страница 14: ...J INSTALLATION INSTRUCTIONS 13 contact customer service support Qomotop com ...

Страница 15: ...s Ensure that there is no obstruction to air ventilation Be sure all gas connections are tight and there are no leaks Be sure the access panel is clear of debris Be sure any component removed during assembly or servicing is replaced and fastened prior to starting FOR YOUR SAFETY WARNING Do not use an open flame to check for leakage Do not smoke during testing Do not test indoors A leak check must ...

Страница 16: ...it turn the control knob to desired heat output position between MIN and MAX Flame Characteristic Normally the burner flame is yellow If the burner flame is blue and very small please check the gas cylinder as it may be low gas pressure or empty If there is enough gas in the cylinder please contact customer service to change the burner of the gas fire pit If flames lift away from burner or backfir...

Страница 17: ...ressure is not enough Please refill gas cylinder Re light 1 Turn the control knob to OFF position 2 3 Repeat steps beginning with step 3 of the lighting instruction Shut down instructions 1 Push in and turn control knob clockwise to OFF position 2 2 Turn LP cylinder valve to OFF position The Event of Gas Leakage 1 Turn the control knob to OFF position 3 Wait 5 minutes to allow gas to dissipate 4 I...

Страница 18: ...ating of outdoor patios decks spas pools and open working areas Always make sure that adequate fresh air ventilation is provided Follow the spacing tolerances shown in Fig 17 at all times This gas fire pit must be placed on level firm ground Never operate in an explosive atmosphere Keep away from areas where gasoline or other flammable liquids or vapors are stored or used LOCATING FIRE PIT FOR USE...

Страница 19: ... replaced Keep the appliance area free and clean from combustible Check if there are cracks or worn sections on the hose If yes please call our customer service to replace hose materials gasoline and other flammable vapors and liquids not obstructing the flow of combustion and ventilation air keeping the ventilation opening s of the cylinder enclosure free and clear from debris Gas fire pit does N...

Страница 20: ... cylinder is disconnected tightly install the threaded valve plugs and do not store it in a building garage or any other closed area You may store product indoorsONLY if the cylinder is disconnected and removed s l a i r e t a m e l b i t s u b m o c m o r f e e r f d n a r a e l c a e r a fire pit e h t p e e K gasoline and other flammable vapors and liquids If you do not use a cover store this o...

Страница 21: ... days from date of purchase Warranty does not cover Freight and packaging charges to and from our customer service center remain the customer s responsibil ity Labor or material charges to remove or replace parts are not covered under this warranty Any floor sample sales or clearance sales from the store are not covered by this warranty Furniture used for com mercial purposes failures caused by im...