background image

PARTS DESCRIPTION

1
2
3
4
5

Air Outlet
Control Panel 
Front Panel 
Castor
Air Inlet 

Air Exhaust Hose Housing
Power Cord 

Lower Drainage Outlet (Drain water when

at end of season before storing the unit in cooling mode.)

6
7

8

1

3

4

2

5

7

8

6

tank is full or

(Drain water all the time when it in heating mode.)

P4

Part

Description

Air Exhaust Hose

Exhaust Hose Housing Adaptor

Exhaust Hose Window Connector

Remote Control

Window Slider Kit

Screws 

Drain Hose

1

1

1

1

1

2

1

Quantity

Содержание PAC8000-2101

Страница 1: ...PORTABLE AIR CONDITIONER with HEAT 8000 BTU DOE SACC Rating USER MANUAL Model PAC8000 2101...

Страница 2: ...ONS P5 REMOTE CONTROL FUNCTIONS P6 INSTALLATION GUIDE P6 Important Tips Install Preparation Exhaust Hose Installation Window Kit Installation OPERATION MODES SETTING P8 Cooling Mode Dehumidifying Mode...

Страница 3: ...is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction c...

Страница 4: ...refrigerants Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer Be aware that the refrigerants may be odorless Compliance with national...

Страница 5: ...tlet Drain water when at end of season before storing the unit in cooling mode 6 7 8 1 3 4 2 5 7 8 6 tank is full or Drain water all the time when it in heating mode P4 Part Description Air Exhaust Ho...

Страница 6: ...F 1 8 Cooling Mode Indicator B Mode Selection 2 9 Dehumidifying Mode Indicator C Increase Temperature Time 7 Temperature or Time Display D Decrease Temperature Time 3 12 Fan Mode Indicator E Fan Speed...

Страница 7: ...ore installation place the unit upright at least 1 hour to allow the refrigerant to stabilize 2 1 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 POWER UP DOWN SPEED MODE SWING TIMER SLEEP DISPLAY ON OFF Increase Tem...

Страница 8: ...min and max size of the window before installation Install the window slider kit on the window Fig 10 Fig 10a Adjust the length of the window slider kit according to the window width or height and fi...

Страница 9: ...are outlet with other appliances Power supply is AC 115V 60Hz Fuse specification T3 15A 250V Cooling Mode Dehumidifying Mode Fan Mode Display Setting Remote control setting Timer Setting Remote contro...

Страница 10: ...mode unplug the lower drain cap Troubleshooting Possible Causes Water full fault alarm and water tank is full The doors or windows are not closed There are heat sources inside the room Exhaust air hos...

Страница 11: ...t Open the air inlet grill and to remove air filter And clean the air filter with neural detergent in lukewarm 104 F and dry it in the shade Warranty is for the original purchaser that the product wil...

Отзывы: