background image

1. Mount the IQ Hardwire 16 vertically in your desired location.  
2. Install provided antenna into the “ANT” terminal at the top of the unit free from 

obstructions

3. Wire all hardwired sensors/leads into the terminals marked “Zone 1-16”

a. All sensors must have a resistor installed between 1k-10k Ohm in either the N/O or N/C position
b. Wire the Positive and Negative leads from powered devices, such as motion sensors and glass break 

sensors, into the “AUX” (+) and “GND” (-) terminals to power the device. (see wiring diagram)

c. Wire the tamper switch into the tamper terminals. (optional)
d. Wire optional hardwired siren (60VDC/1A Max, see wiring diagram)

4. If learning the IQ Hardwire 16 into the Panel for supervision, plug in a 5Ah Max backup 

battery with included battery leads (battery not included).

5. With provided transformer, connect power supply leads into the terminals 16.0V 

GND then plug in the IQ Hardwire 16’s power supply. (IMPORTANT: dashed wire is positive)  

INFORMATION

The 

IQ Hardwire 16 

offers a cost effective way of integrating hardwired security zones 

with the IQ Panel.  It includes backup battery charging, an onboard siren relay and 
features end-of-line resistor learning, making rewiring different resistor values a thing of 
the past. It also supports magnetic contacts and powered zones such as motion sensors 
and glass break detectors. 

Note:  Not for use with life safety devices, such as Smoke or CO detectors

TECHNICAL SPECIFICATIONS

Input Voltage:

 16.0VDC Plug-In Transformer

Backup Battery: 

12VDC 5AH Max (optional)

Dimensions:

 5.5” X 3.5”

Operating Temperature: 

32 to 122F (0 to 50C)

Humidity: 

95% RH Max

EOL Supervision: 

1K to 10K Ohm

Input Zones: 

16 (must have resistor)

Zone Type:

 N/O or N/C compatible

Auxiliary Voltage Output: 

12VDC @ 500mA

Tamper Zone:

 Optional zone input for tamper

Relay Contact: 

60VDC/1A Max drives siren or 

other device

Document #: IQHW16QG
Revision Date: 5/26/15
Qolsys Part #: QS7121-840

STEP 1: INSTALL THE HARDWARE

IN THE BOX

IQ Hardwire 16
Cover
Antenna
Power Supply
4 Screws
16 Resistors (3K)
Battery cables

If mounting inside a metal 
can, the antenna must extend 
outside the enclosure to 
ensure RF communication

QUICK GUIDE

Confidential & Proprietary.

Made in Taiwan.  

Full installation manual and 

other documentation available 

at Qolsys.com.  

Trip the module 
by “shorting” 
the “Tamper” 
terminals on the 
module with a 
piece of wire.  

STEP 2: PAIR THE IQ HARDWIRE 16 WITH THE IQ PANEL

Note:  This allows the IQ Panel to supervise the IQ Hardwire battery, power 
status, aux power out, & tamper

Settings Enter installer 

code

(Default is 1111)

Installation

Security 

Sensors

Auto Learn 

Sensor

Press and hold 
“EOL Learn” for 1-2 
secs.  

(

all Zone 

LED’s flash and 
then turn off)

EOL Cal LED 
will turn ON.  
This puts the 
module into 
“Enroll Mode”.  

Follow the onscreen 
prompts on the IQ 
Panel to finish the 
enrolling process.  The 
IQ Hardwire 16 should 
be learned in as a 
“Hardwire Translator”