Fault phenomenon
Cause analysis
Solution
As the heating lamp is light and
the footswitch is pressed, the
pressure bar is not moved down
The footswitch is out of work
Check if the cis position signal
is slight when pressing the
footswitch (if not, please replace
the switch.)
Press the foot switch and move
the pressure bar down. Move up
the pressure bar immediately
after loosening the foot switch.
The upper sensor
Check if the sensor switch is
slight.
Misplacing retraction gas nozzle
sensor to the gas nibble in
vacuum
Check if the sensor switch is
slight.
Misplacing front-pushed air
nozzle sensor to the gas nibble in
vacuum
When you select a vacuum state
and turn on the footswitch, then
put the gas nozzle forward and
check whether “cis” position
signal is lightning.
The middle sensor
When the sponge touch bag and
is in a preparing contact state,
check if “cis” position signal is
lightning.
Sealing stops running,the
heating light extinguishes,
Start the sensor
Check if the cis position signal is
bright when starting heating.
TROUBLESHOOTING