2 – Installation
D000024-000 Rev. A
2-21
Q
5. Following the reboot, bring up Chassis Viewer. The 12X ports will be displayed
as shown in
Figure 2-10
where the initial port for the group (port 16) has its
LED on. The other ports of the group have their LEDs turned off.
Figure 2-10. 12X Ports Enabled
6. From the 9024 main page, click on the menu buttons
Port Stats/IB Port Stats
to displays the IB Port Statistics screen. The 12X port (for combined ports 16
through 18) is displayed as shown in
Figure 2-11
:
Figure 2-11. 12X Port Statistics
The first port of the group (port 16) is shown as
active
and
Up
, while the other
two ports in the group are displayed as
down
and
Disabled
.
2.3.7.6
SilverStorm 9000 Component LEDs
2.3.7.6.1
Chassis Status LED
The chassis status LED (one per hemisphere) is
Green
when the system is
functioning normally.
The chassis status LED is
Amber
when one of the following conditions exists:
❥
The system ambient temperature exceeds 52 C but remains less than 60 C.
❥
Any Fan Alarm is amber.
❥
Any power supply AC OK LED is off.
❥
Any power supply DC OK LED is off
❥
Any spine module Attention LED is on, or it has been determined that a spine is
not functioning (even if it is unable to light the LED).
Содержание SilverStorm 9000
Страница 1: ...D000024 000 Rev A Page i Q S i m p l i f y SilverStorm 9000 Hardware Installation Guide...
Страница 2: ...SilverStorm 9000 Hardware Installation Guide Q Page ii D000024 000 Rev A...
Страница 10: ...1 Introduction Technical Support 1 4 D000024 000 Rev A Q...
Страница 38: ...2 Installation Installation Tasks 2 28 D000024 000 Rev A Q...
Страница 50: ...Regulatory Compliance Information B 6 D000024 000 Rev A Q...