background image

2 – Installation

D000024-000 Rev. A

2-21

Q

5. Following the reboot, bring up Chassis Viewer. The 12X ports will be displayed 

as shown in 

Figure 2-10

 where the initial port for the group (port 16) has its 

LED on. The other ports of the group have their LEDs turned off.

Figure 2-10. 12X Ports Enabled

6. From the 9024 main page, click on the menu buttons 

Port Stats/IB Port Stats

 

to displays the IB Port Statistics screen. The 12X port (for combined ports 16 
through 18) is displayed as shown in 

Figure 2-11

:

Figure 2-11. 12X Port Statistics

The first port of the group (port 16) is shown as 

active

 and 

Up

, while the other 

two ports in the group are displayed as 

down

 and 

Disabled

.

2.3.7.6

SilverStorm 9000 Component LEDs

2.3.7.6.1

Chassis Status LED

The chassis status LED (one per hemisphere) is 

Green

 when the system is 

functioning normally. 

The chassis status LED is 

Amber

 when one of the following conditions exists:

The system ambient temperature exceeds 52 C but remains less than 60 C.

Any Fan Alarm is amber.

Any power supply AC OK LED is off.

Any power supply DC OK LED is off

Any spine module Attention LED is on, or it has been determined that a spine is 
not functioning (even if it is unable to light the LED).

Содержание SilverStorm 9000

Страница 1: ...D000024 000 Rev A Page i Q S i m p l i f y SilverStorm 9000 Hardware Installation Guide...

Страница 2: ...SilverStorm 9000 Hardware Installation Guide Q Page ii D000024 000 Rev A...

Страница 3: ...ons are suitable for the specified use without further testing or modification QLogic Corporation assumes no responsibility for any errors that may appear in this document No part of this document may...

Страница 4: ...ation Guide Q Page iv D000024 000 Rev A 2007 QLogic Corporation All rights reserved worldwide First Published March 2007 Printed in U S A QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo CA 92...

Страница 5: ...Install the Rack Rails 9024 CU 9020 9040 9080 9120 9240 2 6 2 3 5 Install the Rail Hat Sections 9024 9020 and 9040 2 7 2 3 6 Rack Mount the Switch 2 9 2 3 7 Installing the Switch Fascia 2 11 2 3 8 Ho...

Страница 6: ...SilverStorm 9000 Hardware Installation Guide Page vi D000024 000 Rev A Q B 2 Regulatory Compliance Information B 5...

Страница 7: ...ection 1 describes the intended audience and technical support Section 2 describes the hardware installation and initial configuration tasks Appendix A provides product specification information Appen...

Страница 8: ...s QLogic direct customers may contact QLogic Technical Support others will be redirected to their authorized maintenance provider Visit the QLogic support Web site listed in Contact Information for th...

Страница 9: ...e MN 55344 3657 USA QLogic Web Site www qlogic com Technical Support Web Site support qlogic com Technical Support Email support qlogic com Technical Training Email tech training qlogic com North Amer...

Страница 10: ...1 Introduction Technical Support 1 4 D000024 000 Rev A Q...

Страница 11: ...ur post 19 rack to facilitate easy maintenance Universal mounting rail hole pattern identified in IEC Standard 297 Mounting holes flush with the rails to accommodate the chassis NOTE Operation is subj...

Страница 12: ...manager mounted above connectors to avoid unnecessary weight on the cable bundles Bundle cable using velcro straps to avoid injuring cables Keep all ports and connectors free of dust Untwisted Pair U...

Страница 13: ...stallation process refer to Appendix B 1 Check the installation site to verify the installation of cabinet power feeds rails and grounding 2 Unpack the equipment and inspect for any shipping damage An...

Страница 14: ...n this section 1 If applicable remove the doors of the rack 2 Mark the rack allowing the applicable amount of vertical space to install each switch 3 Install the hat rail sections 9024 9020 and 9040 4...

Страница 15: ...emblies One pair of top support rail assemblies 9240 only Two heyclips 9080 and 9120 Four heyclips 9240 only Kit Mounting Hardware 3 8 Square Hole containing 10 32 x 0 375 pan head Phillips screws Cag...

Страница 16: ...les chassis fan side in the front of the rack NOTE The 2 front holes should match up with the top and bottom holes of the rail front flange All holes should correspond to the rail mounting positions 2...

Страница 17: ...specific left and right part numbers Left switch rail 200595 Right switch rail 200594 Two additional ways to ensure that the rails are mounted on the correct side s of the switch Make certain that th...

Страница 18: ...e hat rail has 8 holes 4 correspond to the left side of the chassis and 4 correspond to the right When installing the hat rails make certain that the top of the rail is installed the same on both side...

Страница 19: ...nd from the front of the cabinet slide it onto the rails The fans and power supplies are on the front of the chassis leaf VIC modules are to the rear CAUTION Never lift the switch with the handles on...

Страница 20: ...r side as shown in Figure 2 6 Figure 2 6 Top Rail Assembly a When complete the top rail assembly should look like Figure 2 7 Figure 2 7 Completed Top Rail Assembly Connect the top rail to rack with 1...

Страница 21: ...of the fascia in place 2 3 7 1 Installing the Modules 9020 9040 9080 9120 and 9240 NOTE The purchased configuration for the SilverStorm 9000 is shipped fully populated Follow these steps when it beco...

Страница 22: ...backplane As the module seats in the chassis the handles will begin to close 5 Push the handles in to fully close NOTE Be sure that all cards are fully inserted in their respective chassis slots and...

Страница 23: ...ovide strain relief for the IB cable connector NOTE When handling IB connectors make certain to remove the connectors by pulling on the center of the lanyard only as shown in Figure 2 9 below Pulling...

Страница 24: ...crossover serial cable for the console port The settings for the terminal emulation device should be 8 data bits no parity bits 1 stop bit 57600 baud Use VT100 emulation Flow control XON XOFF 3 Verif...

Страница 25: ...m ands 5 To change the switch default IP address enter s et Chas s i s I pAddr h i paddr es s m net M as k where h ipaddress is the new IP address in dotted decimal i e xxx xxx xxx xxx format and m ne...

Страница 26: ...the IP addresses are not unique collisions will occur causing IP operations to fail To update the IP address on a managed spine do the following 1 Ensure that the spine module is connected to a COM p...

Страница 27: ...H z Conf i gur ed M em or ySi z e 0x08000000 ChannelI nt er l eaveBi t 0 Num berofM em Channel s 1 Tes t i ng m em or y M em or yt es t spas s CPU0 f l us hi ng caches L2 f l us h com pl et e St ar t...

Страница 28: ...1 gat ewayi net g us er u f t p f t p pas s wor d pw bl ank us er s h f t p f l ags f 0x0 t ar getnam e t n s t ar t up s cr i pt s ot her o s be Loadi ng packagef r om f l as h devi ce i m age1 Boot...

Страница 29: ...f ul l Dupl ex 0 f l owCont r ol 0 s be1 s peed 100 f ul l Dupl ex 1 f l owCont r ol 0 NOTE ThecommandspineipchangestheIPaddressfor image1andimage2 on each managed spine 2 3 7 5 Enabling 12X Ports 902...

Страница 30: ...port using ports 16 through 18 do the following NOTE Ports are combined in groups of three sequentially For example each 9024 has the following possible combinations Ports 1 through 3 Ports 4 through...

Страница 31: ...re 2 11 12X Port Statistics The first port of the group port 16 is shown as active and Up while the other two ports in the group are displayed as down and Disabled 2 3 7 6 SilverStorm 9000 Component L...

Страница 32: ...ED associated with each hemisphere of the system This LED is Blue if Fabric Manager license is installed and enabled on this switch or if Subnet Manager is running anywhere else in the fabric 2 3 7 6...

Страница 33: ...ue IB link status LED that provide the following indications On the logical link is up port is in the Active state Off the physical link is down port is in the Down state 2 3 7 7 2 Module Status LED T...

Страница 34: ...Blink fast low signal to noise ratio SNR close to an error condition Off when an auto negotiation is in progress or an error condition exists 2 3 7 8 FVIC Fibre Channel Port LEDs 9020 9040 9080 9120...

Страница 35: ...spine Off indicates that the management board is in the standby mode if the STAT LED is Green In a redundantly managed system if the Capable LED is also Green this would indicate the slave spine DDR S...

Страница 36: ...s complete when it becomes visible within the Chassis Viewer GUI Listed below are the approximate times to fully update each module type Spines modules up to 4 minutes Leaf VIO modules up to 2 minutes...

Страница 37: ...1 Place the unit into the slot Slowly slide the fan unit in until it engages into the connector 2 Using the panel screw push up to re engage the unit 3 Tighten the captive panel screw 2 3 8 3 Hot Swa...

Страница 38: ...2 Installation Installation Tasks 2 28 D000024 000 Rev A Q...

Страница 39: ...It is recommended to use rack with minimum of 36 depth to facilitate cable installation and routing Other physical attributes are shown in the table below NOTE The 9000 series MPFD products should no...

Страница 40: ...0 264V AC 47 63Hz 1 Phase 2 2A max current at 100VAC Inrush Current 33A 115VAC 25 C cold start 16 5A 230VAC 25 C cold start Power Factor 0 95 Two IEC 320 connectors for independent AC inputs A 4 Cooli...

Страница 41: ...Temperatures of all major heat producing components are continuously monitored by system management modules Fan speed is monitored and automatically adjusted by system management modules to maintain a...

Страница 42: ...ependent DC outputs which are labeled as hemispheres see figure A 1 The lower hemisphere is powered by the lower 6 supplies and the upper hemisphere is powered by the upper 6 supplies There are four i...

Страница 43: ...um configurations are shown in Table A 3 Additional configuration restrictions are documented in this section The maximum number of Virtual I O Controllers VICs per switch is shown in Table A 5 Table...

Страница 44: ...red While DC redundancy is supported for all valid configurations AC redundancy is limited The maximum AC redundancy configurations for the 9120 and 9240 are displayed in Table A 6 Table A 6 9120 and...

Страница 45: ...ct all power cords before servicing unit B 1 1 1 Anweisung 1 Ger t trennen Diese Komponente verf gt m glicherweise ber mehrere Netzkabel Trennen Sie alle Netzkabel bevor Sie die Komponente warten um d...

Страница 46: ...and fingers out of the power supply bays and backplane areas B 1 3 1 Anweisung 3 Gefahr vor elektrischem Schock Um der Gefahr vor elektrischem Schock vorzubeugen halten Sie H nde und Finger den Netzt...

Страница 47: ...ment 6 Equipment Installation Only qualified personnel should be allowed to install remove or replace chassis or modules B 1 6 1 Anweisung 6 Ger teinstallation Die Installation Entfernung oder Erneuer...

Страница 48: ...se Module sind f r die Installation in MPFD Grundeinheiten der SilverStorm 9000 Serie vorgesehen Installieren Sie stets leere Module wenn Sie ein aktives Modul entfernen Diese verhindern dass Stromgef...

Страница 49: ...nce that may cause undesired operation Canada ICES This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe A est conforme a la norme NMB 003 du Canada Europe...

Страница 50: ...Regulatory Compliance Information B 6 D000024 000 Rev A Q...

Отзывы: