
5 – Diagnostics/Troubleshooting
Power-On Self Test Diagnostics
5-4
59265-00 A
S
Internal Firmware Failure Blink Pattern
An internal firmware failure blink pattern is 2 blinks followed by a two second
pause. The 2-blink error pattern indicates that the firmware has failed, and that the
switch must be reset. Momentarily press and release the Maintenance button to
reset the switch.
Fatal POST Error Blink Pattern
A system error blink pattern is 3 blinks followed by a two second pause. The
3-blink error pattern indicates that a POST failure or a system error has left the
switch inoperable. If a system error occurs, contact your authorized maintenance
provider. Momentarily press and release the Maintenance button to reset the
switch.
2 seconds
2 seconds
Содержание SANbox 5802V
Страница 1: ...59265 00 A SANbox 5802V Fibre Channel Switch Installation Guide Firmware Version 7 2...
Страница 36: ...2 General Description Switch Management 2 12 59265 00 A S Notes...
Страница 84: ...4 Installation Installing Feature License Keys 4 20 59265 00 A S Notes...
Страница 104: ...6 Removal Replacement Power Supply Removal and Replacement 6 4 59265 00 A S Notes...
Страница 118: ...SANbox 5802V Fibre Channel Switch Installation Guide Glossary 6 59265 00 A S Notes...
Страница 124: ...SANbox 5802V Fibre Channel Switch Installation Guide Index 6 59265 00 A S Notes...