background image

Corporate Headquarters

    QLogic Corporation    26650 Aliso Viejo Parkway    Aliso Viejo, CA 92656    949.389.6000           

www.qlogic.com

Europe Headquarters 

  QLogic (UK) LTD.    Surrey Technology Centre    40 Occam Road Guildford    Surrey GU2 7YG UK    +44 (0)1483 295825

D A T A   S H E E T

Host Bus Interface Specifications

Bus interface

 PCI Express x4

Memory

1-MB SRAM per port
1-MB flash (SPI)
2-KB NVRAM (SPI)
2-KB EEPROM (I

2

C)

Hardware platforms

Dell PowerEdge 1855
Dell PowerEdge 1955

Compliance

PCI Express Base Specification, rev. 1.0a
PCI Bus Power Management Interface 
Specification, revision 1.1

Fibre Channel Specifications

Data rate

2/1 Gbps auto-negotiation (2.125/1.0625 Gbps)

Performance

150,000 IOPS per port

Topology

Point-to-point (N_Port)
Arbitrated loop (NL_Port)
Switched fabric (N_Port)

Logins

Support for F_Port and FL_Port login
2,048 concurrent logins and 2,048 active 
exchanges per port

Protocols

FCP (SCSI-FCP)
FC-TAPE (FCP-2)










Compliance

SCSI-3 Fibre Channel Protocol (SCSI-FCP)
Fibre Channel Physical and Signaling Interface 
(FC-PH)
Fibre Channel Physical and Signaling Interface 
2nd Generation (FC-PH-2)
Third Generation Fibre Channel Physical and 
Signaling Interface (FC-PH-3)
Fibre Channel—Arbitrated Loop (FC-AL-2)
Fibre Channel Fabric Loop Attachment Technical 
Report (FC-FLA)
Fibre Channel—Private Loop Direct Attach 
Technical Report (FC-PLDA)
Fibre Channel Tape (FC-TAPE) profile
SCSI Fibre Channel Protocol-2 (FCP-2)
Second Generation FC Generic Services (FC-
GS-3)
Third Generation FC Generic Services (FC-GS-3)
Fibre Channel Framing and Signaling (FC-FS)

Physical Specifications

 Ports

Dual 2-Gbps Fibre Channel

 Form factor

Dell PowerEdge mezzanine card

Environment and Equipment 
Specifications

Airflow

No airflow required

Temperature

Operating:  0°C/32°F to 55°C/131°F
Storage:  -40°C/-40°F to 70°C/158°F

Humidity

Relative (non-condensing):  5% to 95%
Storage:  5% to 95%

Power dissipation

4.7W (maximum)








Tools and Utilities

Management tools

SANsurfer FC HBA Manager
SANsurfer FC HBA Command Line Interface (CLI)

Device utilities

FLASUTIL for updating:

Firmware
Boot code
HBA parameters

Boot support

BIOS

APIs

SNIA HBA API V2
SMI-S
FDMI

Operating systems

Windows Server

®

Linux – Red Hat

®

Linux – SuSE

®

VMware

Ordering Information

The QME2462 is available directly from Dell. 
Visit 

www.dell.com

.









SANblade QME2462

© 2007 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide.  QLogic, the QLogic logo, QLA, and SANblade are registered trademarks of QLogic Corporation.  PowerEdge is a registered trademark of Dell Inc.  
All other brand and product names are trademarks or registered trademarks of their respective owners.  Information supplied by QLogic Corporation is believed to be accurate and reliable.  QLogic Corporation assumes no responsibility for any errors in this 
brochure.  QLogic Corporation reserves the right, without notice, to make changes in product design or specifications.

CU0358001-00 A  07/07