Qlogic iSR6140 Скачать руководство пользователя страница 2

D A T A   S H E E T

iSR6140

 Universal SAN Connectivity

 

SN0058074-00  A 

2

Corporate Headquarters

    QLogic Corporation    26650 Aliso Viejo Parkway    Aliso Viejo, CA 92656    949.389.6000           

www.qlogic.com

Europe Headquarters 

    QLogic (UK) LTD.      Quatro House      Lyon Way, Frimley     Camberley Surrey, GU16 7ER UK     +44 (0) 1276 804 670

© 2008 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic and the QLogic logo are registered trademarks of QLogic Corporation. 

 

All other brand and product names are trademarks or registered trademarks 

of their respective owners. Information supplied by QLogic Corporation is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to make changes 
in product design or specifications.

Interface Specifications

Gigabit Ethernet

Two ports: copper 1000 BaseT, RJ45

 

Full duplex, auto negotiating 100/1000 Mbps

 

Fibre Channel

Two optical ports

 

Full duplex

 

Auto negotiation: 2 Gbps or 1 Gbps

 

N_ports, NL_ports, F_ports, FL_ports, E_ports

 

Class 2, 3 connectionless

 

Management port

Ethernet 10/100 BaseT with RJ45

 

RS-232 serial port with RJ45

 

iSCSI Initiator Support

Microsoft

Windows Server 2000, 2003, 2008

 

Solaris

SPARC 2.6, 8, 9, 10

 

x86

 

Linux

Red Hat AS 3, 4, 5

 

SUSE Enterprise Server 8, 9, 10

 

VMware

ESX Server v3.x

 

AIX

AIXL 5

 

HP-UX

HP-UX 9, 10

 

QLogic

4010, 4050, 4052, 4060, 4062

 

Apple

OS X (via ATTO driver)

 

Protocols

iSR6140

iSCSI to FCP

 

CHAP Security and Authentication

 

 Performance Features

Fibre Channel port speed

2-Gbps, full-duplex, auto negotiating for 

 

compatibility with existing 1-Gbps devices

Ethernet/iSCSI port speed

1-Gbps, full-duplex, auto negotiating for 

 

compatibility with existing 100-Mbps devices

Maximum data rate

320 MBps aggregate

 

Input/output operations per second (IOPS)

35,000 aggregate

 

Ports per chassis

Two FC, Two Ethernet/iSCSI

 

FC: hot-pluggable, standard SFPs

 

Ethernet/iSCSI: RJ45

 

Supported SFP types

Shortwave (optical)

 

Longwave (optical)

 

Cable types

Optical (FCI): 50/62.5 micron multi-mode fiber

 

9 micron single-mode fiber

 

Unshielded twisted pair (Ethernet/iSCSI)

 

Cat 5e or better

 

Interoperability

Compatible with FC-SW-2 complaint switches

 

Management interoperability with leading SAN 

 

management applications

Device Management

Management methods

Wizard-based configuration tools

 

Command line interface (CLI)

 

SNMP and SMI-S

 

Access methods

Dedicated out-of-band Ethernet 10/100 BaseT, 

 

RJ45

Diagnostics

Power-on self-test (POST) of all functions

 

User interface

LED indicators, CLI, and web utilities

 

Mechanical

Enclosure types/options

Optional side-by-side rack mount kit

 

Dimensions

Width: 177.8 mm (7.00”) – half rack

 

Height: 42.16 mm (1.66”) (1U)

 

Depth: 243.58 mm (9.59”)

 

Power supply

48W maximum (optics included) 

 

100 VAC to 240 VAC; 50 Hz to 60 Hz

 

0.5A at 100–125 VAC; 0.25A at 200–240 VAC

 

Cooling

Two fans with back-to-front airflow

 

Environmental/Safety

Operating

Temperature: +5°C to +40°C (41°F to 104°F)

 

Humidity: 5% to 90% non-condensing

 

Altitude: 0 to +10,000 ft.

 

Vibration: IEC 68-2, 5-500Hz, random, 0.21G 

 

rms, 10 minutes
Shock: IEC 68-2, 4g, 11ms, 20 repetitions

 

Non-operating

Temperature: -40°C to +70°C (-40°F to 158°F)

 

Humidity: 5% to 93% non-condensing

 

Altitude: 0 to +50,000 ft.

 

Vibration: IEC 68-2, 5-500Hz, random, 2.09G 

 

rms, 10 minutes
Shock: IEC 68-3, 30g, 292 ips, 3 repetitions, 3 

 

axis

Agency

UL 60950 (USA)

 

CSA 22.2 No. 60950 (Canada)

 

EN 60950 (EC)

 

CB Scheme-IEC 60950

 

Отзывы: