2–Configuring NIC
NIC TroubleShooting/Diagnostics
SN0054671-00 A
2-53
Windows Diagnostic Test Messages
If a test fails, an appropriate error code is generated and displayed, as shown in
Table 2-9
. Note that this table does not list error messages for the interrupt and
link tests.
Table 2-9. Windows Diagnostic Test Messages
Test
Error Message
Description
Loopback
LB_TEST_OK
Loopback test has passed
LB_SEND_WAIT_QUEUE_E
RR
Send queue blocked
LB_NORCV_ERR
Receive packet not received
LB_NOMEM_ERR No
memory
error
LB_TX_QUEUE_ERR
Transmit queue error
LB_SHORT_DATA_ERR
Looped data short error
LB_SEQUENCE_ERR
Looped data out of sequence
LB_DATA_ERR
Looped data corrupted
LB_ERR_CNT
Looped error count
Register
CR_TEST_OK
Control register test passed
CR_NIU_MODE
Network interface unit (NIU) error
CR_PHY
Physical layer (PHY) error
CR_ERRCNT
Control register error count
Hardware
HW_TEST_OK
Hardware test has passed
HW_DMA_BZ_0
DMA channel 0 is busy
HW_DMA_BZ_1
DMA channel 1 is busy
HW_DMA_BZ_2
DMA channel 2 is busy
HW_DMA_BZ_3
DMA channel 3 is busy
Содержание 8200 Series
Страница 1: ...SN0054671 00 A User s Guide Converged Network Adapter 8200 and 3200 Series...
Страница 18: ...Preface Legal Notices xviii SN0054671 00 A...
Страница 46: ...1 Product Overview Installing the QLogic Adapter vCenter Plug in for ESX ESXi 1 24 SN0054671 00 A...
Страница 71: ...2 Configuring NIC Teaming Bonding SN0054671 00 A 2 25 Figure 2 9 Creating an 802 3ad Static Team...
Страница 72: ...2 Configuring NIC Teaming Bonding 2 26 SN0054671 00 A Figure 2 10 Creating an 802 3ad Dynamic Team...
Страница 104: ...2 Configuring NIC NIC TroubleShooting Diagnostics 2 58 SN0054671 00 A Figure 2 26 NIC Troubleshooting Diagram 2...
Страница 122: ...A Adapter LEDs A 2 SN0054671 00 A...
Страница 128: ...User s Guide Converged Network Adapter 8200 and 3200 Series Adapters Glossary 6 SN0054671 00 A...
Страница 129: ......