lnstallation lnstructions - Outdoor Unit
Step 1: Select installation location
Before installing the outdoor unit, you must choose an appropriate location. The following are standards
that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
•
Meets all spatial requirements shown in lnstallation Space Requirements above.
•
Good air circulation and ventilation
•
Firm and solid - the location can support the unit and will not vibrate
• Noise from the unit will not disturb others
• Protected from prolonged periods of direct sunlight or rain
•
Where snowfall is anticipated, raise the unit above the base pad to prevent ice buildup and coil
damage. Mount the unit high enough to be above the average accumulated area snowfall.
The minimum heigh must be 18 inches
DO NOT install unit in the following locations:
•
Near an obstacle that will black air inlets and outlets
•
Near a public street, crowded areas, or where noise from the unit will disturb others
•
Near animals or plants that will be harmed by hot air discharge
•
Near any source of combustible gas
•
In a location that is exposed to large amounts of dust
•
In a location exposed to a excessive amounts of salty air
SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
lf the unit is exposed to heavy wind:
lnstall unit so that air outlet fan is at a 90° angle to the direction of the wind. lf needed, build a barrier in
front of the unit to protect it from extremely heavy winds.
See Figures below.
lf the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air
flow around the unit.
lf the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist corrosion.
Step 2: lnstall drain joint(Heat pump unit only)
Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note
that there are two different types of drain joints depending on the type of outdoor unit.
Strong wind
Strong wind
Strong wind
Wind Baffle
4
man_S60xx SCAN ('21) V4.indd 120
man_S60xx SCAN ('21) V4.indd 120
09-11-2021 09:07
09-11-2021 09:07
Содержание S60 Series
Страница 45: ...45 6 man_S60xx SCAN 21 V4 indd 45 man_S60xx SCAN 21 V4 indd 45 09 11 2021 09 07 09 11 2021 09 07 ...
Страница 89: ...89 FIN man_S60xx SCAN 21 V4 indd 89 man_S60xx SCAN 21 V4 indd 89 09 11 2021 09 07 09 11 2021 09 07 ...
Страница 133: ...133 4 man_S60xx SCAN 21 V4 indd 133 man_S60xx SCAN 21 V4 indd 133 09 11 2021 09 07 09 11 2021 09 07 ...
Страница 177: ...177 u man_S60xx SCAN 21 V4 indd 177 man_S60xx SCAN 21 V4 indd 177 09 11 2021 09 07 09 11 2021 09 07 ...
Страница 221: ...221 man_S60xx SCAN 21 V4 indd 221 man_S60xx SCAN 21 V4 indd 221 09 11 2021 09 07 09 11 2021 09 07 ...
Страница 265: ...265 man_S60xx SCAN 21 V4 indd 265 man_S60xx SCAN 21 V4 indd 265 09 11 2021 09 07 09 11 2021 09 07 ...