![Qlima LK 1051 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/qlima/lk-1051/lk-1051_operating-manual_765976017.webp)
33
32
with odor and should be changed frequently. In winter, at room temperature
lower than 0 degree, it is necessary to remove the water and clean with dry
towel to avoid frost.
5. In cleaning the outer surface of the unit, wet cloth (or with some detergent)
should be used. Do not use any corrosive cleaner or solvent for this purpose.
Rinsing with water is absolutely not allowed. (F.7)
6. If packed for storage or transportation, please drain the water and make the
unit working a few minutes, after totally dry then pack it, in order to avoid the
peculiar smell.
7. Don’t keep the plug connecting when long time no using the unit, it will be
damaged.
8. If the supply cord is damaged, it must be replaced by the manufacture or its ser-
vice agent or a similarly qualified person in order to avoid a hazard.
9. The unit has strong humidity effect, please shut this function in the airtight
environment.
10. Filling water when it is in the low water level.
11. This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
se of the appliance by a person responsible for their safety.
12. Children should be supervised to ensure that they do not play with the appli-
ance.
ELECTRICAL SCHEMATIC DIAGRAM
M: Fan Motor
M1: Swing Motor L/R
M2: Water Pump
C: Control board
W: Water level sensor
TECHNICAL SPECIFICATIONS
Model
Voltage
Input
Power
Noise
Power
Level
Water
Tank
Capacity
Evapora-
tion
Capacity
Air Flow
Rate
N.W. Dimension(mm)
L X W X Hdel
Lk1051
AC220-
240V,50Hz
65W
50dB(A)
9.5 l
1.2L/h
510m3/h
5.3
kg
360×275×703
Remark:
1.The water consumption is depend on the environment’s humidity.
2.The above datum are for reference only. Users should refer to parameter on the rating label.
C
W
4
4
FUNCTIONS OF ALL BUTTONS
HOW TO CHANGE BATTERY FOR THE CONTROLLER
1: Pull the battery outward.
2: Put in the new battery with the“+”on the top.
3: Put the battery box in thecontroller
CAUTION
1. Use normal power supply. (F.5)
2. Do not place objects on the top of the unit. Do not cover the air outlet when in
use and obstructed of front and back in one meter. (F.6)
3. After filling with water, do not tilt or collide the unit, when you need to move
the unit, push the side surface slowly so as to avoid water splashing out. Do not
overturn the unit in service to prevent accident.
4. The body of the unit may not be place in area with extremely high or low tem-
perature. In hot summer, the water in its water tank is liable to deterioration
ON/OFF
Switch on this button to open the air cooler , with a short sound“BI” signaling the starting of normal
operation. Meanwhile, functions indicators for cooling and swinging(normal wind type) are turned
on automatically. Medium windy from the starting after 3 seconds, it will change to low speed.
To close the air cooler, switch off the “ON/OFF” button. A short sound of “BI” signals stop of all
operation.
MODE
The Normal mode is set automatically after opening the air cooler. Pressing this button will switch
the Normal mode to sleep. Pushing it again will switch the sleep mode to Natural. All of the three
types are available for choice. (Remark: When the “Natural” or “Sleep” mode is on, the wind speed
will not be changed).
COOL
This function is started automatically after opening the air cooler. To stop cooling function, push the
button. To press it once more will open this function again. (When the cooling function operates,
fans automatically t Remark: urn to low speed 30 seconds).
SWING L/R
This function is started immediately after opening the air cooler, shown by the lighted SWING L/R
indicator. Under this condition, the wind board slowly sways form left to right. To stop this function
as well as the indicator, just push this button. Pushing it once more will start the swaying of wind
board once again.
SPEED
Push this button to change the speed of wind after starting the air cooler. Wind speed can be chan-
ged from low, medium to high. Indicator for low wind speed turns on when the air cooler works in
low speed. So do medium and high speed indicators.
TIMER
The timer function turn on when press this button on standby mode, and can set timer power on
from 1 hour to 7.5 hours by hour. After turn on the machine, press this button to set timer power off
function from 1 hour to 7.5 hours by hour. Release this function can press this button to change the
time and can press “ON/OFF”button directly.
LED
The LED display panel light and the control light turn on at the same time when the machine is on.
The LED display panel will turn off automatically after 10 seconds from the unit is off but the control
light will not turn off.
WATER LEVEL The LED light is blue when the tank have water, The Led is red and the machine also make voice
alarm when water is lacking in tank. The water is lacking if the machine is in cooling mode, need to
add water and press cooling button to turn cooling function.
1)
2)
1
2
3
Содержание LK 1051