Information requirement for the electric local space heaters
Model identifier(s): EOR 1515 LCD
Item
Symbol Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
Pnom
1,50
kW
manual heat charge control, with integrated thermostat
No
Minimum heat output
(indicative)
Pmin
0,60
kW
manual heat charge control with room and/or outdoor temperature
feedback
No
Maximum continuous heat
output
Pmax,c
1,50
kW
electronic heat charge control with room and/or outdoor
temperature feedback
No
Auxiliary electricity consumption
fan assisted heat output
No
At nominal heat output
elmax
1,455
kW
Type of heat output/room temperature control (select one)
At minimum heat output
elmin
0,589
kW
single stage heat output and no room temperature control
No
In standby mode
elSB
0,002
kW
Two or more manual stages, no room temperature control
No
with mechanic thermostat room temperature control
No
Seasonal space heating energy
efficiency
ɳ
s
36,6%
with electronic room temperature control
Yes
electronic room temperature control plus day timer
No
electronic room temperature control plus week timer
No
Other control options (multiple selections possible)
room temperature control, with presence detection
No
room temperature control, with open window detection
No
with distance control option
No
with adaptive start control
No
with working time limitation
No
with black bulb sensor
No
Contact details
PVG Holding BV, P.O. Box 96, 5340 AB OSS, Kanaalstraat 12c, 5347 KM OSS, THE NETHERLANDS