57
Ash on the
floor around
the stove
Flue pipes are not air-
tight
Only to be done by an approved flue fit-
ter: Flues that are not airtight can harm
your health. Seal the pipe fitting immedi-
ately (use Loctite 598 or equivalent prod-
uct) and/or replace the pipes.
Broken, worn or dam-
aged door seal
Replace the seal. Only to be done by a
Qlima-approved technician
Stove in con-
stant mode,
the display
shows: "Eco"
The room temperature
desired by the user has
been reached
This is not an error. The stove is working in
eco mode. This mode can be changed with
the remote control
Display shows
"SERV"
No error. The stove
requires a service every
1200 hours of operation.
The stove will simply
continue to work.
The stove requires a service. Contact a
Qlima-approved service technician. The
technician will carry out a service on the
stove and reset the notification.
Display shows
"Atte"
An attempt is being
made to start the stove
while it is still in the
cooling-down phase.
Wait until the cooling down phase has
been completed before trying to reignite
the stove.
Stove goes
out. The alert
shown is “AlAr
/ dEp / Sic /
Fail” and the
LED 5 will be
shown on the
display.
Pressure sensor/switch is
defective
Replace the pressure switch. Only to be
done by a Qlima-approved technician
The exhaust/flue/chimney
is blocked
Have the exhaust/flue/chimney cleaned im-
mediately by an approved chimney sweep.
Contact an approved chimney sweep.
Electronic printed circuit
board is defective.
Replace the electronic printed circuit
board. Only to be done by a Qlima-ap-
proved technician
Excessive flue length
Consult a flue specialist to check whether
the flue complies with the law. Consult
a Qlima-approved technician to check
whether the flue is suitable for the stove.
Unfavourable weather
conditions
Strong winds can cause negative pressure
in the flue. Check and restart the stove.
Stove is overheating
Room temperature too low. Open doors
to other rooms. If the problem persists,
contact a Qlima-approved technician.
The safety thermostat on the stove has
been triggered. Let the stove cool down,
then reset the safety thermostat by remov-
ing the protective cap (figure 16) and
pressing the reset button (figure 17).
The room air recircula-
tion blower is defective
Replace the blower. Only to be done by a
Qlima-approved technician
Temporary power outage
A power cut when the stove is in opera-
tion can cause the interior to overheat. Al-
low the heater to cool down and restart it.
Safety thermostat is
defective
Replace the safety thermostat. Only to be
done by a Qlima-approved technician