• Do not modify the appliance. This is to
avoid hazardous situations arising. Any
modifications made would result in the
warranty becoming null and void.
• Store the installation and operating man-
ual in a safe place.
• In an emergency, always follow the instruc-
tions given by the fire brigade.
3. POSITION THE ROOM TEMPERATURE SENSOR
The room temperature sensor is located at the back of the stove. Unwind the sen-
sor cable until the sensor tip is 10 cm from the floor (see Figure 1). Make sure that
the sensor does not come into contact with hot parts of the stove.
4. MINIMUM REQUIREMENTS FOR THE FLUE PIPE/CHIMNEY
The chimney/flue pipe is a very important part of the system.
This chapter deals with the minimum requirements that the chimney/flue pipe for
the pellet stove must meet to ensure the stove works properly.
G
Comply with the rules, provisions, regulations and legislation in force
at local/national level. If the installation instructions contained in this
manual deviate from the current legislation at local, national and/or
regional level, the latter is prevalent.
The manufacturer and distributor expressly disclaim any liability in the event that:
•
Installation fails to comply with national/local legislation.
•
If national/local legislation is not applicable, the minimum system require-
ments described in this document may not need to be complied with.
4.1 MINIMUM REQUIREMENTS THAT THE CHIMNEY MUST MEET
1.
Only one device can be connected to the fireplace. Do not connect multiple
appliances to a single chimney. Never connect two stoves, a suction hood
and a stove, a second chimney, etc. to a single chimney. See Figure 2.
2.
Use only approved installation material when installing the chimney. The
pellet stove's chimney must be heat-resistant (minimum 450° C). Consult the
rules, regulations, and local/national legislation governing the requirements
of materials for chimney installation.
3.
The chimney and its outlet must be positioned at a sufficient distance from
combustible and inflammable materials. Consult the rules, regulations, and
local/national legislation governing the requirements for these materials.
4
Instal_man_ECO1700('20)V6.indd 47
Instal_man_ECO1700('20)V6.indd 47
30-07-20 16:54
30-07-20 16:54
Содержание ECO 1700
Страница 39: ...39 2 Instal_man_ECO1700 20 V6 indd 39 Instal_man_ECO1700 20 V6 indd 39 30 07 20 16 54 30 07 20 16 54...
Страница 89: ...89 1 Instal_man_ECO1700 20 V6 indd 89 Instal_man_ECO1700 20 V6 indd 89 30 07 20 16 54 30 07 20 16 54...
Страница 110: ...110 1 2 3 Instal_man_ECO1700 20 V6 indd 110 Instal_man_ECO1700 20 V6 indd 110 30 07 20 16 54 30 07 20 16 54...
Страница 116: ...116 5 6 7 Instal_man_ECO1700 20 V6 indd 116 Instal_man_ECO1700 20 V6 indd 116 30 07 20 16 54 30 07 20 16 54...
Страница 117: ...117 8 9 Instal_man_ECO1700 20 V6 indd 117 Instal_man_ECO1700 20 V6 indd 117 30 07 20 16 54 30 07 20 16 54...
Страница 118: ...118 Instal_man_ECO1700 20 V6 indd 118 Instal_man_ECO1700 20 V6 indd 118 30 07 20 16 54 30 07 20 16 54...
Страница 119: ...119 Instal_man_ECO1700 20 V6 indd 119 Instal_man_ECO1700 20 V6 indd 119 30 07 20 16 54 30 07 20 16 54...