4
Terminal block
Terminal Box Wiring Instructions
Parts Definition/ Installation
• First, machine taps or holes on the mounting surface.
• The mounting hole of this product is 8mm(SEDL/ SEDLP/ SDL/ SDLP only), 11mm(SMDL/ SMDLP only)mm in diameter(hole).
• When machining taps, fasten the bolt through the mounting hole of the product.
• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface
• When assembling using bolt and nut, please make sure to use flat washer and spring washer.
■
Parts Definition
■
Installation
• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper
body to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire for
secure connection.
• Please wire the Power line to terminal
①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.
①
Lens
(PC)
Housing
(Al)
(SEDLP, SDLP, SMDLP only)
Volume Adjustment
• The volume output of this product is adjustable.
•
Turn the volume dial clockwise to increase the volume, and
turn counter clockwise to decrease the volume.
• There will be no sound when the dial is put at MIN.
Volume Dial
VOL.
MIN.
MAX.
Protection cage(STS316L)
Horn housing
※
Applicable cable range : AWG16-AWG22