Please place the product on desired surface area and
secure it with brackets (either horizontal or vertical dir
ection is possible).
• Insert the lens tube (1) into the bracket (3) in the
direction indicated in the diagram (2). Adjust the
lighting direction (4) to the desired position.
• Washer M5 (7) and bolt M5 (6) to the
bracket in the direction indicated in the diagram (5).
• External power line – UL TYPE TC(1277) PVC-NYLON/PVC 3C 18AWG 700mm
• This product can be wired regardless of polarity.
■
Parts Definition
■
Bracket Adjustment
QLEX-NEC-250
Dimensions
(Units : mm)
Wiring Instructions
Grounding Instructions
Parts Definition/ Bracket Adjustment
•Please use an M4 bolt at the location marked in the diagram
above to ground the product.
• When connecting the grounding cable, please use a ring
terminal(Ø5.2mm).
• Please use a grounding cable with a diameter greater than4mm.
• Please make sure to ground the common line(-) of theproduct.
3