Grounding Instructions

Mounting Hole Specifications

Parts Definition/ Installation

Installation Environment and Protection Rating

 

This product is designed to be explosion proof. 

 

Please make sure to use the product in an environment that meets the specified explosion proof rating and regulations.

 

For further information, please visit our website (www.qlight.com).

• STB45ML-EX can be wired by using both external contact and transistor.

• In case of wiring by transistor, please make sure if it is NPN type or PNP type. Please carefully follow wiring instruction below.

Wiring Instructions

• External power line/ external signal line - UL2464 AWG22(0.3sq) 400mm
• This product can be wired regardless of polarity. 

STB45ML-EX-DC

STB45ML-EX-DC

Red
Amber
Green
Blue

White
Brown

Black

Red
Amber
Green
Blue
White

Brown

Black

Red
Amber
Green
Blue
White

Brown

Black

Layer1
Layer2 
Layer3 
Layer4 
Layer5 

Buzzer

Buzzer

Buzzer

Layer1
Layer2 
Layer3 
Layer4 
Layer5 

Layer1
Layer2 
Layer3 
Layer4 
Layer5 

Power

Power

Power

Fuse

Fuse

Fuse

Steady

Steady

Steady

EXTERNAL TRANSISTOR-NPN

EXTERNAL TRANSISTOR-PNP

EXTERNAL CONTACT

• Machine holes on the mounting surface referring to the 
  diagram below.

M4 ground 

contact part

Cover(ABS)

Lens(PC)

Housing(PC)

• First, remove the flange nuts from bolts and place the 

  product through the mounting surface holes.

• Fasten the flange nuts on the opposite side of the mounting 

  surface until the product is tightened securely.

• Please use an M4 bolt at the location 

  marked in the diagram above to ground 

  the product. 

• When connecting the grounding cable, 

  please use a ring terminal.

• Please use a ring terminal made of C5212  

  material as it has the same electrical prop-

  erties of the conductor. 

• Please use a grounding cable with a 

  diameter greater than 4mm.

Sound volume lever

Buzzer Sound Volume Adjustment Instructions

Buzzer volume is reduced by sliding 

the volume control lever to the left as 

show in the diagram to the left.

(Min. 65dB/m) 

Raise/ Increase the buzzer volume 

by sliding the control lever to the right 

as shown in the diagram to the left.

(Max. 83dB/m

)

Flange nut 

Cover(AI) -T6 only

3-Ø5 HOLES

Ø17 GABLE GLAND HOLE

PCD 30