Qlight ST45ML-Ex Скачать руководство пользователя страница 3

Rev.1.1 

2016.06.14 

•Earth by using M4 spring washer head screw(STS type)
•In case of earth wiring, use 0 type terminal (internal diameter

4.2) on the body.

•O  type  terminal  shall  be  made  of  C5212  or  same  level  of
conductor.
•Diameter of the earth wire shall be 4 mm or higher.
•Common line (-)must be grounded.

9. How to wiring

Both  power  line  and  signal  line  come  out.  Power  &  sound
line shall be interconnected. Refer to wiring diagram as below. 

■DC Steady type

Specification : UL1007-NO.22(0.3sq) 400mm

Connect black line and negative(-) line each other

10. How to install

This  product  is  intended  for  indoor  use  only.  Do  not  use  for

outdoor use.

Install  vertically  as  much  as  possible.  Avoid  vibration  and

impact.

Pierce  appropriate  holes  on  the  place  to  be  installing  the

product in advance by referring below hole size.

Direct Mounting type shall be fixed by using the nuts(M4-3EA)

bottom of the product.

ST45ML-Ex 

Series 

PCD 30, Ø5x3 

11. Trouble Shooting

Symptom

 

Reason

 

Solution

 

No light 

Wiring error 

Check wiring 

Dim light 

Supply  lower  voltage 
than 

standard 

requirement 

Check voltage 

LED  signal  lights  cannot 

be divergence partially 

Supply  higher  voltage 
than 

standard 

requirement 

LED 

damage 

Check voltage 

- Customer Service -