2
SPK-CAN
62
62
4-Ø4.5 HOLES
Ø66 HOLES
•
When wiring with power line, please check the voltage at the terminals.
①
Dimensions
(Units : mm)
Wiring Instructions
Parts Definition/ Installation / Mounting Hole Specifications
•
Machine holes on the mounting surface referring to
the diagram below.
■
Mounting Hole Specifications
■
Parts Definition/ Installation
Front cover(ABS)
Bolt
Housing(ABS)
Packing
• First, machine taps or holes on the mounting surface
①
.
• The mounting hole of this product bracket is 4.5mm in diameter.
• When machining taps, fasten the bolt through the mounting hole of the bracket.
• When machining holes, insert the bolt through the hole of the bracket, and tighten the nut from the opposite side of the mounting surface.
80
80
75
15
60
62
4-M4 BOLT
62
Micro USB
MAX.
Volume
+ COM -
DC10-36V
GND L(A) H(B) NC
T-REG
NC
RS-485
CAN
Ø65
Ø6
5
NC
T-REG
NC
GND
CAN-H
CAN-L
POWER
DC12V~24V
Fuse
•
How to set ‘T-REG’
- If the product is installed at the end of CAN Networks, please add a terminating resistor to the ‘T-REG (Terminating Resistance)’ position of the
rear terminal blocks of the product.
- The capacity of the terminating resistor is recommended with 120Ω/0.5W.