Qlight SHD Скачать руководство пользователя страница 3

3

Installation Environment and Protection Rating

• This product is designed for use with protection rating of IP66.

• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating 

   indicated(IP66), it may cause malfunction or damage to the product.

• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-

  down positions where water can potentially penetrate into the product and impact it’s operation.

• For further information, please visit our website (www.qlight.com).

Parts Definition/ Installation

• 

First, machine holes on the mounting surface.

• 

The mounting hole of this product is 8.5mm in diameter.

• 

When machining taps, fasten the bolt through the mounting hole of the bracket. 

• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface. 
• When assembling using bolt and nut, please make sure to use flat  washer and spring washer.

Mounting Hole Specifications

/

Light bulb Replacement lnstructions

• Machine holes on the mounting surface referring to the 
  diagram below.

4-Ø9 HOLES

134

87

■ 

Mounting Hole Specifications

Terminal Box Wiring Instructions

• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper
   body to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the 
  wire for secure connection.
• Please wire the power line to terminal 

• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.

• Please wait at least 

1

 minute after turning off the power 

  before replacing the bulb.

• In order to dissemble the bulb, please push down the bulb(

  lightly and screw it counterclockwise.

• In order to put the bulb in to the unit, please place the bulb(

  in the socket(

) and screw it clockwise while lightly pushing 

  down the bulb.

Assemble bulb

Disassemble bulb

■ 

Bulb Replacement Instructions

Horn

Lens

(PC)

Housing

(Al)

Protection cage

(STS316L)