2
3
4-Ø9 HOLES
108
108
Parts Definition/ Installation
• Machine holes on the mounting surface referring to
the diagram below.
Grounding Instructions
Mounting Hole Specifications
• Please use an M4 bolt at the location marked in the diagram
above to ground the product.
• When connecting the grounding cable, please use a ring
terminal.
• Please use a grounding cable with a diameter greater than 4mm.
•
First, machine taps or holes on the mounting surface
①
.
•
The mounting hole of this product is 8mm in diameter.
•
When machining taps, fasten the bolt through the mounting hole
of the product.
•
When machining holes, insert the bolt through the hole of the
product, and tighten the nut from the opposite side of the
mounting surface.
■
Installation
■
Parts Definition
Bell(Al)
Housing(Al)
Cover(Al)
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP56.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP56), it may cause malfunction or damage to the product.
• For further information, please visit our website(www.qlight.com).
M4 ground contact part
Terminal Box Wiring Instructions
• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper body
to get rid of the upper lighting element of the unit.
• Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire for
secure connection.
• Please wire the power line to terminal
①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.
• External power line -
UL1015 AWG18(0.75sq) x 2C 400mm
①