background image

2

• First, machine holes on the mounting surface.
• Remove the M4 nuts from bolts and place the product 

  

  through the mounting surface holes.

• Fasten the M4 nuts on the opposite side of the mounting

 

  surface until the product is tightened securely.

• 

S80SM models have strong magnets at the base of the 

  product that allows attachment to any metal surface.

■ Installation

Wiring Instructions

• DC/AC type cable specification : 

External power line -

 UL1015 AWG18(0.75sq) x 2C 400mm(S80S)

                                                          External power line -

 IEC42(0.75sq) x 2P 2000mm(S80SM)

• For S80SM models, please connect the cigarette lighter plug of the product to a cigarette lighter socket of a vehicle.
• DC type product can be wired regardless of polarity.

Dimensions

(Units : mm)

Ø83

Ø83

Ø10 HOLES

Ø10 HOLES

S80SM

S80S

10

6

16

84

15

10

6

84

16

(0.75sq) x 2P 2m

PCD 50

360°/3-M4 BOLT

360°/3-

Ø

22 MAGNET

PCD 50

S80S

S80SM

Parts Definition/ Installation

■ Parts Definition

Lens(AS)

Housing(ABS)

Magnetic mounting base

Xenon bulb 

Flange nut

Rubber spacer

Flat washer

DC

AC

Red

Black

Power

Fuse

White

Black

Power

Fuse