Qlight S80RK Скачать руководство пользователя страница 2

2

Parts Definition/ Installation

Mounting Hole Specifications

Bulb Replacement Instructions 

• 

First, remove the flange nuts from bolts and place the product 

  through the mounting surface holes.

• 

Fasten the flange nuts on the opposite side of the mounting surface 

  until the product is tightened securely.

• Machine holes on the mounting surface referring to

  the diagram below.

Wiring Instructions

Dimensions

(Units : mm)

Reflector

(Heat resistant ABS)

Lens(AS)

Light bulb

Housing(ABS)

Flange nut

Bolt

Ø13 CABLE 

ENTRY

Ø83

Ø84

360°/3-

Ø5 HOLES

S80RK

82

71

153

PCD 70

Ø13 CABLE 

ENTRY

Ø83

Ø84

S80UK

PCD 70

155

71

84

360°/3-

Ø5 HOLES

PCD 70

3-Ø5 HOLES

Min. Ø5 CABLE ENTRY

S80RK/ S80UK

• Please wait at least 

1

 minute after turning off the power 

  before replacing the bulb.

• In order to dissemble the bulb, please push down the bulb

(

)

 

  lightly and screw it counterclockwise.

• In order to put the bulb in to the unit, please place the bulb

(

)

 

  in the socket(

) and screw it clockwise while lightly pushing 

  down the bulb.

Assemble bulb

Disassemble bulb

• External power line - 

UL1015 AWG18(0.75sq) x 2C 400mm

• AC compatible type shall be connected the black and white wires when using AC110V, and the black and red wires when using 
  AC220V.

DC

AC compatible type 

AC

Red
Black

Red
White
Black

White
Black

Power

Power

Power

Fuse

Fuse

Fuse