4
360°/3-
Ø6
HOLES
Min. Ø5
CABLE ENTRY
PCD70
①
②
▶
LF : Flash
ing
▶
L : Steady
Installation Environment and Protection Rating
• This product is designed for use with protection rating of IP54.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP54), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
•
For further information, please visit our website (www.qlight.com).
• Machine holes on the mounting surface referring to the
diagram below.
• Please refer to the chart below to use light function
selection switch located inside the product.
• Default function is set at steady LED. Select the desired
function for your application during installation.
Assemble bulb
Disassemble bulb
Light Function Selection/ Mounting Hole Specifications
Light bulb
/
Xenon Bulb Replacement lnstructions
■
Light Function Selection(100DL only)
■
Bulb Replacement Instructions(S100D model only)
■
Mounting Hole Specifications
■
Xenon Bulb Replacement instructions
(
S100DS
only
)
①
②
•
Please wait at least 30 mimutes after turning off the power before
replacing the xenon bulb.
• Please pull out the entire xenon bulb structure
①
to disassemble.
• For xenon bulb assembly, please ensure the connector portion of
the xenon bulb structure matches the pin location
②.
Disassemble
xenon bulb
Assemble
xenon bulb
• Please wait at least
1
minute after turning off the power
before replacing the bulb.
• In order to dissemble the bulb, please push down the bulb
(
①
)
lightly and screw it counterclockwise.
• In order to put the bulb in to the unit, please place the bulb
(
①
)
in the socket(
②
) and screw it clockwise while lightly pushing
down the bulb.