background image

 

Deprogramming all user cards: 

-    To deprogram all user cards, hold the Admin card that was used to program the user cards in front of the lock 

for  about  5  seconds  until  it  flashes  red  one  time,  remove  the  card;  Then  hold  the  Admin  card  again  about  5 

seconds until it flashes red twice, remove the card.   

-    All user cards that were programmed with this Admin card will be deprogrammed at the same time. If several 

Admin cards are used, this procedure will have to be carried out separately for each Admin card.       

-    The Admin card remains valid. 

 

 

 

III. Additional instructions   

 

Timeout: 

-

 

The  programming  or  deprogramming  mode  is  terminated  when  no  action  is  carried  out  (i.e.  the  card  is 

neither introduced nor removed) for approximately 10 seconds. 

-

 

The programming or deprogramming mode will be stop when the action is incorrect (flashes red) 

-

 

When the RFID lock is unlocked with a user card, the door has to be opened within 5 seconds. otherwise, 

the RFID lock will relock automatically. 

 

Visual Indications 

-

 

Green light flashing (3 times) for the below cases:         

-

 

1) The RFID card was recognised, i.e. this card has already been programmed with this particular LOCK.   

-

 

2) Confirmation that the action (programming or deprogramming) was successfully completed. 

-

 

Red light blinking for the below cases:     

-

 

1) The RFID card was not recognised, i.e. this card has not yet been programmed with this particular LOCK.     

2) Presented the wrong card when programming or deprogramming 

 

Public / Private Mode   

When the lock is in private mode there are no visual indications 

When the lock is in public mode locks that are in use will flash red every 5 seconds to show that they are in use 

 

Emergency Opening 

-      Unlock by Admin key if losing the user card or by the mechanical master key. The master key can be used to 

open the lock at any time. This does not affect the lock programming in any way.

 

 

Low battery alarm   

-The alarm will sound if the battery is low and the LED will flash red 5 times warning users to replace the battery 

soon. 

 

Changing the Battery   

1.

 

Remove fixing screw   

2.

 

Rotate the lock down over the edge of door 

3.

 

Take out the batteries   

4.

 

Put in the new batteries and screw lock back into place 

www.qilocks.com         [email protected]         +44 (0)20 8906 6881

Содержание PL730

Страница 1: ...70mA Use condition Temperature 15 65 Humidity 5 95 Features Works with most Mifare solutions 13 56MHz Three level system for user administration Quick and easy operation No external programming devices needed LED in 2 colors for lock status green red Application for metal wooden and plastic doors Can be used right left handed on door thickness up to 20mm Handle Induction Area Emergency opening Ite...

Страница 2: ... public mode a red light will flash every 5 seconds to indicate the locker is in use Change from Private use into Public use Hold Main admin card to lock for 1 2 seconds green light flashes 3 times then repeat again for 3 seconds until green light flashes setup successfully Repeat the above process to switch back to Private use How to operate the lock Open Present the User card Admin card to the l...

Страница 3: ...the battery cover press the reset button until the lock flash 4 times then release the button reset successfully Deprogramming individual Admin cards Hold the Main Admin card in front of the lock for about 5 seconds green light flashes 3 times until it flashes red one time remove the card After that the Admin card to be deprogrammed is held for approximately 5 seconds in front of the lock green li...

Страница 4: ...ashing 3 times for the below cases 1 The RFID card was recognised i e this card has already been programmed with this particular LOCK 2 Confirmation that the action programming or deprogramming was successfully completed Red light blinking for the below cases 1 The RFID card was not recognised i e this card has not yet been programmed with this particular LOCK 2 Presented the wrong card when progr...

Отзывы: