FLUO SENS integrated Manual 

January 2013 

 

9  Operation  

 

 is  configured  and  operated  exclusively  via  MODBUS-ASCII 
commands. No further operation elements are necessary.  

 

9.1  MODBUS-ASCII 

 

The  MODBUS  Protocol  was  developed  and  released  by  the 
company MODICON in the early 1980s. It is primarily employed 
in  the  area  of  process  automation.  Because  it  is  an  open 
protocol  and,  if  nothing  else,  its  simple  structure,  it  is  widely 
used.  In  the  meantime,  the  MODBUS-IDA  Organization  is 
responsible for the maintenance and continuing development of 
the protocol. Numerous documents can be obtained. 

 

MODBUS is based on a master/slave system. The master is a 
superordinate controller, for example a PC or a programmable 
controller.  The  MODBUS  Controllers  in  the  FLUO  SENS 
integrated are slave devices. 

There are no bus conflicts, since only a single node sends at a 
time. The master requests communication. This request can be 
directed  to  a  specific  node  or  sent  out  as  a  message  to  all 
nodes. The nodes receive the request and send, independently 
of the type of request, a reply to the master.  

 
 

 

 
 
 
 
 

 
MODBUS communication is implemented as follows: 

 

M

MODBUS  serial  communication via serial  interfaces such 
as RS232, RS485  

 

M

MODBUS  ASCII  codes  the  data  using  ASC-II  character 
set in the form of legible character chains  

 
 

MODBUS  works  according  to  the  Master/Slave  principle.  A 
master  can  communicate  with  one  or  more  slaves.  Only  slaves 
explicitly permitted by the Master can return data to the Master. 
 
The  protocol  supports  both  binary  and  16-bit  values,  which  are 
read in block-form by the Master. Neither quality recognition, nor 
time stamps are supported. 

 

Содержание FLUO SENS

Страница 1: ......

Страница 2: ...Manual...

Страница 3: ...s Trademarks and labels used are the property of their respective owners Copyright Information User Manual for FLUO SENS integrated Document Number ESMO30 DH 1001 Document Revision 05 January 2013 Cop...

Страница 4: ...8 3 Switching off the Device 12 9 Operation 13 9 1 MODBUS ASCII 13 10 Configuring a MODBUS Protocol 14 10 1 Longitudinal Redundancy Check LRC 14 10 2 MODBUS Function Codes 14 10 3 Function Code 03 Re...

Страница 5: ...tors or for online measurements in automated processes The confocal optics allows contact free measurements on surfaces and in liquids in the presence of ambient light The highly sensitive detector me...

Страница 6: ...ion wavelengths 265nm 980nm Available detection wavelengths 365nm 980nm Specifications given in the list above are for reference only Exact specifications for the individual detectors are given in the...

Страница 7: ...pe 150mA The FLUO SENS integrated features a 10way flex cable in the rear part of the housing see 4 1 and 4 2 This flex cable is used for communication and power supply Dimensions are shown left Flex...

Страница 8: ...etector is connected to ground return To achieve precise alignment between the detector and the sample the front lens is designed with a 8f8 fit shown bottom left ESMO40 MB xxxx Detector Dimensions 4...

Страница 9: ...5 C Relative Humidity 20 to 70 rel humidity 5 1 Environment If you plan to use the device in a working environment prone to dust and dirt you will need to clean the device regularly For cleaning use a...

Страница 10: ...ay heat up in normal operating mode Tip Never touch the detector s optics Danger Do not look directly into the optics Detectors emit strong light radiation that can cause permanent damage to the eye D...

Страница 11: ...d 6 1 Start up The is ready for use upon delivery 6 2 Mounting The housing possesses two M3 threads on both long sides for mounting purposes The positions of the threads are given in the drawings in c...

Страница 12: ...devices however the built in drivers limit the number to 64 for RS485 and 16 for TTL versions The MODBUS address for each device must be set at a value between 1 and 254 before being connected Each a...

Страница 13: ...regulations In Germany this includes the VDE and Employer s Liability Insurance Association regulations as well as the stipulations of the EMC directives 8 1 EMC Safety Precautions In the case of inc...

Страница 14: ...ntroller The MODBUS Controllers in the FLUO SENS integrated are slave devices There are no bus conflicts since only a single node sends at a time The master requests communication This request can be...

Страница 15: ...the transmitting device which appends the LRC to the message The receiving device recalculates an LRC during receipt of the message and compares the calculated value to the actual value it received in...

Страница 16: ...EB Value Hi Register 235 00 Number of Registers Hi 00 Value Lo Register 235 00 Number of Registers Lo 02 Value Hi Register 236 00 LRC 07 LRC F1 End Frame CRLF End Frame CRLF 10 4 Function Code 06 Wri...

Страница 17: ...h w trigger until the method is finished Auto trigger measurement Measurement is started at power on all values are taken after one h w trigger Method Type E1D2 Emission on channel 1 detection on chan...

Страница 18: ...Page 17 of 24 FLUO SENS integrated Manual January 2013 10 6 FLUO SENS integrated Memory Allocation...

Страница 19: ...ark For byte parameters in bytes 0 or 2 like Modbus Adress the given values written to the detector must be multiplied by 256 Example Set Modbus Address to 2 you have to write 2 256 512 to the detecto...

Страница 20: ...t value On Value 1 Request 000301040002f6 Response 000304001C5A364D Integer Interpretation 001C5A36h 1858102 counts Conversion counts mV counts 0 000298026 1858102 Counts 553 76mV 10 12 Setting Start...

Страница 21: ...nication via Hyper Terminal 12 The FL Digital Program The FL Digital program allows the user to collect and display data from the FLUO SENS integrated Instrument sensitivity parameters can be setup an...

Страница 22: ...t example in section 10 7 Error No response to MODBUS requests Cause Incorrect MODBUS Address is being used Correction Try communication with MODBUS address 0 Test example in section 10 7 Error No res...

Страница 23: ...s to ensure secure contact Tip If the is operated in high temperature environments the measurement values can deviate somewhat from the real values In this case calibrate the device beforehand under t...

Страница 24: ...rtner has the option to demand a reduction in price or withdraw from the contract The same shall apply if replacement of the product fails or cannot be reasonably expected from QIAGEN Lake Constance G...

Страница 25: ...s are subject to the quality standards in compliance accordance with DIN ISO 9001 QIAGEN Lake Constance GmbH Jacques Schiesser Strasse 3 D 78333 Stockach Germany Website www qiagen com Email info qiag...

Отзывы: