CLEANING INSTRUCTIONS:
T
o clean the pump, remove the front cover. Use a small brush and/or water to remove
any debris. Rinse filter.
CAUTION:
The pump shaft cannot be r
emoved. If the pump fails to operate, follow these steps:
1. Check circuit breaker and try another outlet to ensure the pump is getting electrical
power.
2. Check the pump discharge and tubing for obstructions. Buildup can be flushed out
with water.
3. Check the intake to ensure it is not clogged with debris. Rinse filter.
4. Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is
not broken or jammed.
5. Make sure the electrical cord loops below the electrical outlet to form a "drip loop".
This will prevent water from running down the cord into the electrical outlet.
See illustration for proper assembly and disassembly of your
QEP 60095 water pump.
SEAL RING
Flow Rate By Adjusted Flow
By Height
Per Hour
FT CM GAL/h L/hr 30GAL 150GAL
1
30.5
59
222
0.5
2.5
2
61
54
203
0.56
2.8
3
91.5
48
180
0.625
3.125
4
122
41.5
156
0.72
3.6
5
152.5
33
125
1.1
5.5
6
183
18
67.5
1.7
8.5
Flow Per Hour
SHAFT
MOTORHEAD
IMPELLER
IMPELLER
HOLDER
SUCTION
BRACKET
FRONT PLATE
FLOW ADJUSTER
FILTER