QEP 60007 Скачать руководство пользователя страница 6

CUTTING TABLE

MARKED IN INCHES AND CENTIMETERS FOR ACCURATE CUT DIMENSIONS. 

STEPS FOR

POSITIONING 45° / 90° RIP GUIDE:

1. Set the rip guide by positioning it on the desired dimension and tighten the threaded

knob on the rip guide. Make sure rip guide is firmly tightened to avoid slippage.

2. The rip guide can be used for 90° rip cuts and 45° rip cuts from both the left and right

side! (Notice the straight and 45° angled slits on the bottom of the rip guide in the
diagram.)

3. After the rip guide is positioned for the desired cut, place material flush against the rip

guide and the measurement rail. For 45° rip cuts, place the corner of material in the
open slot of the measurement rail. 

4. Now you are ready to make your cut.

- 6 -

BLADE & BLADE GUARD INSTALLATION

1. Remove the blade guard and set it aside in the cutting head.

2. Raise the blade guard to the highest level and tighten the blade guard wing

screw. Then, remove the blade shaft nut and outer flange.

3. Place the blade onto the shaft, pushing it up against the inner flange. Make

sure the directional arrow is pointing in the direction of rotation.

4. Replace the outer flange and blade shaft nut. With one hand, hold the blade

and tighten the blade shaft nut with your free hand. Make certain the nut is
firmly tightened with wrench provided. DO NOT OVER-TIGHTEN!

5. Lower the blade guard into position and tighten the wing screw.

6. To remove the blade, reverse the installation steps. (See Diagram 2)

ENGLISH

WATER PUMP INSTALLATION

1. Remove the water pump from its box and ensure that it is not cracked or

damaged in any way (See Diagram 3)

2. Attach the end of the plastic tubing, hanging down from the blade guard, to

the water pump nipple.

3. Place the water pump in the rear of the water tray on its side, with the water

pump nipple also on its side.

4. Next, fill the water tray with the water so that its level is higher than the water

intake nozzle.

5. Keep the power cord out of the water and plug it into the 3-prong receptacle

on the back of the cutting head assembly. The pump is activated by the
ON/OFF switch on the electric motor.

NOTE: WATER PUMP SAFETY GUIDELINES & MAINTENANCE INSTRUCTIONS ARE
LISTED BELOW. PLEASE READ CAREFULLY AND COMPLETELY.

WATER PUMP SAFETY GUIDELINES

1. The pump is equipped with a grounding-type attachment plug. Be sure to connect the plug to a properly grounded

grounding type receptacle to reduce the risk of electric shock.

2. When assembling & installing the water pump system, be sure to fully support the pump and piping to reduce the

chance of pump failure or damage.

3. Never handle the pump by the cord, with wet hands or when standing on a wet surface.

4. Do not use the pump to pump anything other than water, or other compatible liquids. Never use to pump gasoline,

kerosene, or other combustible or corrosive liquids.

5. Should pump fail, always disconnect from power source before handling pump or attempting to unclog or service the

pump in any way.

6. Never let the pump operate dry. It is self-cooled by pumping liquid. Dry use will cause pump damage and may cause

the motor to fail.

Содержание 60007

Страница 1: ... avant d utiliser cette scie CAUTION Read and follow all safety and operating instructions before using this saw AVISO Lea y siga todas las instrucciones de funcionamiento y seguridad antes de usar esta sierra Q EP CO INC 1081 Holland Drive Boca Raton FL USA 33487 561 994 5550 Fax 561 241 2830 www qep com ROBERTS CONSOLIDATED INDUSTRIES INC 600 N Baldwin Park Blvd City of Industry CA USA 91749 626...

Страница 2: ...ui n est pas recommandée par Q E P La pompe à eau est exclue de cette garantie et est sujette à la garantie de son fabricant Cette garantie remplace toute autre garantie explicite ou implicite IMPORTANT Afin de valider la garantie la fiche de garantie doit être remplie et reçue dans un délai de trente jours à compter de la date d achat LIMITED WARRANTY This product is covered by a 30 day warranty ...

Страница 3: ...ssories may cause risk of injury 16 NEVER STAND ON TOOL Serious injury could occur if the tool is tipped or if the cutting tool is unintentionally contacted 17 CHECK DAMAGED PARTS Before further use of the tool a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function check for alignment of moving parts binding of...

Страница 4: ...ange a drip loop in the cord connecting the saw to a receptacle The drip loop is that part of the cord below the level of the receptacle or the connector if an extension cord is used to prevent water from traveling along the cord and coming in contact with the receptacle If the plug or receptacle does get wet don t unplug the cord Disconnect the fuse or circuit breaker that supplies power to the t...

Страница 5: ...S Horsepower 1 2 H P Saw duty rated Volts 115V Amps 5 8 RPM 4 000 Cycle 60 Phase 1 Connect saw as close as possible to power source EXTENSION CORDS When using an extension cord ensure all cords are no smaller than 12 gauge rated at a 20 AMP minimum and equipped with 3 prong plugs Use of anything smaller may result in overheating or burn out of the motor It is recommended to have an electrician che...

Страница 6: ...ee Diagram 2 ENGLISH WATER PUMP INSTALLATION 1 Remove the water pump from its box and ensure that it is not cracked or damaged in any way See Diagram 3 2 Attach the end of the plastic tubing hanging down from the blade guard to the water pump nipple 3 Place the water pump in the rear of the water tray on its side with the water pump nipple also on its side 4 Next fill the water tray with the water...

Страница 7: ... Wipe off all exterior surfaces and keep the cutting table clean and free to tile chips and debris 3 Wipe off both the guide bars and the rollers on the cutting table 4 Place light machine oil on the guide bar to facilitate smooth travel of the linear guide assembly 5 The guide bars are specially treated to give you years of operation 6 Always check the blade for cracks or signs of fatigue DOs DON...

Страница 8: ... Grinder 9 Mounting Plate 10 Wing Screw 10 1 Blade Guard 11 Blade Guard Adjustment Knob 11 1 Blade Lock Nut 12 Outer Flange 13 Blade 14 Inner Flange 15 Water Flow Y 16 1 Water Flow L 16 2 Cover for Automatic Overload Switch 17 Waterproof Switch 18 Electrical Cord 19 Electrical Cord Fixed Head Automatic Overload Switch 20 Plate for Single Socket 21 Single Socket 22 Bottom Plate 23 Water Pump 24 Clo...

Отзывы: