   BATTERY

   Before first use or if battery status indicator shows low battery power 

   insert a new battery. Open battery cover and insert a new battery 

   (take care to polarity). Close battery cover again.

   Note

   If instrument cannot be switched on or 

off

 battery has to be replaced.

   CONNECT  PROBE

   Before starting operation connect probe supplied in the kit with the

   socket on top of the instrument housing. Remove the protective

   cover before starting operation.

   OPERATION

   ON/OFF

   Switch instrument on and of with ON/OFF button.

   Remove the lens protection and face the instrument the light source

   in a horizontal position.

   UNITS

   Select the unit requested Lux or Foot-candle (Fc) with button UNITS.

   Determine the measuring range with button APO.

All manuals and user guides at all-guides.com

Содержание FLM 400 Data

Страница 1: ...Bedienungsanleitung User manual Luxmeter Lux Meter FLM 400 Data All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...entfernen Ger t nicht in Kinderh nde gelangen lassen EIGENSCHAFTEN Luxmessger t mit einem Messbereich bis 400 000 Lux Messung in den Einheiten in Lux oder Foot candle Fc Entpricht dem CIE Standard Vol...

Страница 3: ...RWENDUNG Messung der Beleuchtungsst rke in den Einheiten Lux und Foot candle Fc und Auslesen der gespeicherten Daten nach bertragung auf PC Hohe Genauigkeit und kurze Anspechzeit Mit langlebiger Silik...

Страница 4: ...trate 1 5 x Sek Messsonde Silikon Fotodiode mit Spektralfilter Spektralempfindlichkeit CIE photopisch Spektralgenauigkeit CIE V Funktion f1 6 Cosinusempfindlichkeit f2 2 Korrektur bei schr g einfallen...

Страница 5: ...der Fc 7 RANGE APO Auswahl Messbereich 8 BACKLIGHT LOAD Hintergrundbeleuchtung Laden der Daten 9 REC SETUP Speichern Einstellungen 10 MAX MIN Maximum Minimum AUF 11 REL Relative Ablesung Rechts 12 PEA...

Страница 6: ...SONDE ANSCHLIESSEN Vor Inbetriebnahme die mitgelieferte Messsonde mit der daf r vorge sehenen Buchse an der Geh useoberseite fest verbinden Nach Abnehmen der Schutzkappe kann mit der Messung begonnen...

Страница 7: ...ligkeit den gew hlten Messbereich in diesem Fall den n chst h heren Messbereich w hlen Der Messbereich wird unten im Display angezeigt Lux 400 4K 40K 400K Fc 40 400 4K 40K Zur Auswahl des Messbereichs...

Страница 8: ...nktion werden dann mit dem Nullwert in Beziehung gesetzt Dazu Taste REL dr cken Displayan zeige MANU REL Taste REL erneut dr cken um die Funktion wieder zu verlassen USB ANSCHLUSS Ger t ber USB Anschl...

Страница 9: ...tion zu verlassen Das Ger t hat 99 interne Speicherpl tze DATALOGGER Zun chst Zeit und Abtastrate einstellen siehe S 8 die Standard Ab tastrate ist 1 Sek Taste REC SETUP ca 5 Sek gedr ckt halten um di...

Страница 10: ...auteilen 1 500 3 000 Hotel ffentliche R ume Garderobe Waschraum Gep ckraum 100 200 Empfang 200 1 000 Ladengesch ft Treppen Korridor 150 200 Schaufenster allg Tresen 750 1 500 Vorderseite Schaufenster...

Страница 11: ...erplatz INSTALLATION DER SOFTWARE Windows starten Vor der Installation alle laufenden Anwendungen schlie en CD in CD Laufwerk einlegen Eingabe x setup OK Pfad c program files Lightmeter Nun den Instal...

Страница 12: ...datum Die Garantie erstreckt sich nur auf M ngel wie Material oder Herstellungsfehler sowie die Nichterf llung zugesicherter Eigenschaf ten Ein Garantieanspruch besteht nur bei bestimmungsgem er Ver...

Страница 13: ...ch Naturkatastrophen wie z B Erdbeben Sturm Flut usw sowie Feuer Unfall Eingriffe durch Dritte oder einer Verwen dung au erhalb der blichen Einsatzbereiche Der Hersteller und sein Vertreter haften nic...

Страница 14: ...14 All manuals and user guides at all guides com...

Страница 15: ...your local dealer Do not remove warning labels or safety instructions Keep instrument away from children Always keep instrument dry FEATURES Luxmeter with a measuring range up to 400 000 Lux Measurin...

Страница 16: ...arefully Pack it up only if it is perfectly dry Transport in original container case only MAX MIN reading 1 5 measurements per second High accuracy and short response time With long life silicon photo...

Страница 17: ...ate 1 5 times sec Probe Silicon photo diode with spectral response filter Spectral response CIE photopisch Spectral accuracy CIE V function f1 6 Cosine response f2 2 correction for angular incidence o...

Страница 18: ...r Fc 7 RANGE APO selection of measuring range 8 BACKLIGHT LOAD backlight loading of data 9 REC SETUP save setting 10 MAX MIN maximum minimum UP 11 REL relative reading FORWARD 12 PEAK HOLD peak value...

Страница 19: ...Before starting operation connect probe supplied in the kit with the socket on top of the instrument housing Remove the protective cover before starting operation OPERATION ON OFF Switch instrument o...

Страница 20: ...ange selected in this case select the next higher measuring range The measuring range selected is shown on bottom of the display Lux 400 4K 40K 400K Fc 40 400 4K 40K For selection of the measuring ran...

Страница 21: ...value Press button REL to acti vate this function Display indication MANU REL Press button REL again to quit this function USB CONNECTION Connect instrument to PC via USB cable Display indication BACK...

Страница 22: ...surements DATALOGGING First set sampling rate see page 21 standard sampling rate is 1 sec Press button REC SETUP for approx 5 sec to activate datalogging function Display indication in the upper right...

Страница 23: ...ssembly line 1 500 3 000 Hotel Public room cloakroom 100 200 Reception cashier 200 1 000 Store Indoors stairs corridor 150 200 Show window packing table 750 1 500 Forefront of show window 1 500 3 000...

Страница 24: ...ce INSTALLATION OF THE SOFTWARE Start Windows Close all open applications before installing the software Insert CD in the CD drive Enter x setup OK Path c program files Lightmeter Now follow the insta...

Страница 25: ...he date of purchase During the warranty period and upon proof of purchase the product will be re paired or replaced with the same or similar model at manufacturers option without charge for either par...

Страница 26: ...nsequential damage and loss of profits by any disaster earthquake storm flood etc fire accident or an act of a third party and or a usage in other than usual conditions The manufacturer or its represe...

Страница 27: ...27 All manuals and user guides at all guides com...

Страница 28: ...03 2011 Technische nderungen vorbehalten All instruments subject to technical changes All manuals and user guides at all guides com...

Отзывы: