This device is intended only for OEM integrators under the following conditions:

   

1.

 

The antenna must be installed such that 20 cm is maintained between the antenna 

and users, and 

 

2.

 

The transmitter module may not be co-located with any other transmitter or antenna.

   

3.

 

For all products market in US, OEM has to limit the operation channels in CH1 to 

CH11 for 2.4G band by supplied firmware programming tool. OEM shall not 

supply any tool or info to the end-user regarding to Regulatory Domain change.

 

As long as 2 conditions above are met, further transmitter test will not be required. However, 

the OEM integrator is still responsible for testing their end-product for any additional 

compliance requirements required with this module installed (for example: 

Notebook, 

Wireless Router…etc.

).

   

 

IMPORTANT NOTE: 

In the event that these conditions can not be met (for example certain 

laptop configurations or co-location with another transmitter), then the FCC authorization is no 

longer considered valid and the FCC ID can not be used on the final product. In these 

circumstances, the OEM integrator will be responsible for re-evaluating the end product 

(including the transmitter) and obtaining a separate FCC authorization.

   

 

End Product Labeling

 

 

This transmitter module is authorized only for use in device where the antenna may be 

installed such that 20 cm may be maintained between the antenna and users (for example:

 

Notebook, Wireless Router…etc.)

 The final end product must be labeled in a visible area 

with the following: “Contains TX FCC ID: RUJ-Q802XKG”.

   

 

Manual Information That Must be Included

 

 

The OEM integrator has to be aware not to provide information to the end user regarding how 

to install or remove this RF module in the user’s manual of the end products, which integrate 

this module.

   

 

The user’s manual for OEM integrators must include the following information in a prominent 

location “   

IMPORTANT NOTE

: To comply with FCC RF exposure compliance requirements, the 

antenna used for this transmitter must be installed to provide a separation distance of at least 

20 cm from all persons and must not be co-located or operating in conjunction with any other 

antenna or transmitter.

   

 

3

Содержание Q802XKG

Страница 1: ...Q802XKG 802 11b g Wireless PCI Express Mini Card USB Interface User s Manual...

Страница 2: ...Configuring the Wireless LAN Card Connecting to an existing network Configuring the Wireless LAN Card NOTE This product standardized the Radio Frequency Module The system manufacturer is required to...

Страница 3: ...tinue 2 Go to the directory where the Wireless Adapter Installation stored then double click the Setup Program to begin the installation Exsample IS_AP_STA_7x_D 1 1 4 0_2500_D 2 1 0 0_RU 1 2 7 0_AU_1...

Страница 4: ...ext to continue Note If you have installed the Windows XP Service Pack 2 You can use the Windows Zero Configuration Tool for Wireless Configuring Please refer the Windows XP User s Guide 5 Click Next...

Страница 5: ...uring your new software installation 7 The installation is now complete Please click Finish 8 When you complete the installation the utility icon will appear on the system tray You could double click...

Страница 6: ...ess LAN Card 1 For uninstalling the Wireless LAN Card please go to Start Programs Ralink Wireless under Windows environment Then click Uninstall RT7x 2 Select Remove all to uninstall the Wireless LAN...

Страница 7: ...7 3 Wait for removing the driver and utility 4 After completing the uninstallation click Finish to restart your computer...

Страница 8: ...click the utility icon in your system tray to begin the utility configuration Connecting to an existing network Select Site Survey Tab all available Access Points would be listed Click on the desired...

Страница 9: ...le To create a profile click Add type a profile name and set the corresponding parameters If one of the profiles is no longer used you may remove it by clicking the Delete button After changing parame...

Страница 10: ...less Receive and Transmit throughput in Kbits per second Link Quality Signal Strength The Link Quality and Signal Strength bar graph is only active when the node is in Infrastructure Mode The bar grap...

Страница 11: ...nfiguration Tab you may set Power Saving Mode Network Type RTS Threshold and Fragment Threshold Under Add Profile screen Authentication vs Security Tab you may set Authentication Type Encryption Type...

Страница 12: ...12 After fishing the Add Profile Check Profile Tab you may find the new added profile in Profile List z Statistics The Statistics Tab provides information about the Transmit and Receive frames...

Страница 13: ...ers the advanced configuration for user to set the Wireless Adapter under certain network environment These advanced options include Wireless mode B G Protection Tx Rate and Turn On Off RF z QoS QoS T...

Страница 14: ...14 z About About Tab shows the product version including the detail of Configuration Utility Version Driver Version EEPROM Version and NIC MAC Address...

Страница 15: ...an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Opera...

Страница 16: ...lid and the FCC ID can not be used on the final product In these circumstances the OEM integrator will be responsible for re evaluating the end product including the transmitter and obtaining a separa...

Страница 17: ...17 NCC...

Отзывы: