10) Disconnect from mains before maintenance or cleaning.
D
o not use a wet sponge to clean the appliance.
1.
B
efore conducting any cleaning or maintenance work, disconnect the lamp from the electrical supply and wait until it
cools down
2.
N
o abrasive products, solvents, detergent or any other liquid may be used to clean the fan or lamp
3.
B
e sure the power is off when you clean the fan
4.
D
on’t clean the motor, switch house and other electric parts of the fan with water in order to avoid short circuit
11) Trouble shooting
TROUBLE
PROBABLE CAUSES
SUGGESTED REMEDY
1. Fan will not start
A / Fuse or circuit breaker
blown.
B/ Loose power line
connections to the fan.
C/ Speed controller not in
correct position.
A / Check main and branch
circuit fuses or circuit
breakers.
B/ Check line wire connections
to fan
C/ Check speed controller’s
position.
2. Fan sound noisy
A / Top canopy touching
ceiling.
B/ Loose fan blade screws.
C/ Ceiling fan not secured
against ceiling.
D/ Incorrect speed controller.
A / Lower Canopy from
ceiling to ensure minimum 3
mm clearance.
B/ Re-tighten all screws on fan
blades but never over-tighten.
C/ Re-tighten all screws
in the hanging bracket
or plate.
D/ Change the controller to
the one supplied.
3. Mechanical Noise
A / Allow at least for 8
hours settling-in period.
4. Fan Wobbles
A / Fan blades are not
horizontal to ceiling.
B/ Blade screws are loose.
A / Measure from ceiling to tip
of blades, then rotate fan so all
blades are checked for equal
height from ceiling (not
adjustments may be made by
slight pressure up or down on
blade holders). Make sure all
screws are securely fastened.
DYNAMIC BLADE BALANCE KIT
YARDSTICK
MEASURING POINT
P.7