Q4 audio DPI 40 Скачать руководство пользователя страница 5

DPI SERIES USER MANUAL

4

2. Safety Instructions

 

All safety and operation instructions must be read before this 

unit is operated.

 

The safety and operating instructions must be retained with 

the unit for future reference.

 

All warnings on the appliance and in this operation manual 

must be strictly followed.

 

This unit must not be used near water - for example, near 

bathtub, washbowl, kitchen sink, laundry tub, in a wet base-

ment, near a swimming pool, etc.

 

This unit  must be placed away from heat sources, such as 

radiators or other heat producing devices.

 

The power supply cord must be routed so that it is not likely 

to be stepped on or pinched by objects placed on or against 

it.

 

The power cord of the unit must be unplugged from the mains 

outlet if the unit is not used for a longer period.

 

Care must be taken that objects do not fall and liquids are not 

spilled into the inside of the unit.

 

Unplug the unit and demand servicing by qualified service 

personnel under any of the following conditions: 

• 

Objects have fallen, or liquid has been spilled into the unit; 

• 

The unit has been exposed to rain; 

• 

The unit does not appear to operate normally or exhibits a 

marked change in performance; 

• 

The unit has fallen, or its chassis got damaged; 

• 

The power cord or power plug are damaged.

 

The user must not attempt to service the unit beyond those 

means described in this operating manual.  All other servicing 

must be referred to qualified personnel.

 

To prevent electric shock do not use the polarised plug with 

an extension cord, receptacle or other mains outlet unless the 

prongs can be fully inserted to prevent contact exposure.  This 

unit is equipped with a single pole disconnect device (fuse) in 

the phase (live) wire.  If an unpolarised mains connection is 

used, the receptacle the unit is connected to must be equipped 

with a two pole disconnect device (fuse) of appropriate rating.  

The dust filter cover on the front of the unit forms an integral 

part of the electrical safety provisions.  Do not use the unit 

without the dust filter cover in place!

 

Precautions should be taken so that the grounding and mains 

polarisation means of the unit are not defeated.

 

Slots and openings in the unit are provided for ventilation.  To 

ensure reliable operation and to prevent overheating of the 

unit, these openings must not be blocked or covered!

 

The fanguard on the front of the unit is an integral part of the 

safety provisions of the DPI amplifier.  Make sure it is correctly 

mounted before connecting the unit to a mains outlet.

3. DPI series Features

DPI series power amplifiers feature:

 

Switching class D output stage.

 

Fully symmetrical, and floating modulator for unsurpassed 

accuracy and cross channel separation.

 

Open input architecture for future expansion.  The stand-

ard input module PIM-SIM provides

 

inputs on Neutrik® 

Combo connectors or Phoenix screw terminals, parallel link 

outputs on XLR-3M for easy routing of multiple amplifiers and 

selectable high pass filters with 30 and 50Hz second order 

high pass filter characteristic.

 

Instant  recovery,  eliminating  stitching  of  the  output  when 

recovering from clipping or overload. 

 

EFL® (Extended Feedback Loop).  This inovating technique 

makes it possible to take the feedback for the amplifier right 

from the loudspeaker terminals, offering unprecedented con-

trol of the loudspeaker, independent on loudspeaker cable 

length.  The amplifier can be used as a conventional amplifier 

without this feature enabled, without any inconveniences.

 

Defeatable clip limiter with selectable response time.

 

Minimum sample frequency  selection.

 

Protection against over-dissipation, open or short circuit and 

HF or DC at the output.

 

Outputs on touch proof Neutrik® Speakon connectors and 

high  current  Phoenix®  screw  terminals.    Speakons  have 

integral sensing inputs for the EFL circuit. 

 

Low flux toroïdal power transformer with thermal sensing.  

The  output  power  of  the  amplifiers  is  reduced  in  case  of 

overheating.

 

Extensive power line filtering for minimal interference.

 

Soft start to minimise current surge on power on.

 

A high efficiency cooling system.  The power transistors are 

mounted  directly  onto  the  heatsink,    eliminating  the  high 

thermal  resistance  of  electrical  insulators.   This  reduces 

component temperatures and extends the life of the power 

components.

 

Temperature proportional speed fans for quiet operation.

 

Front to back air flow.

 

Easy to clean air filter on the front.

Содержание DPI 40

Страница 1: ...DPI Series User manual Prelimenary Professional Power Amplifiers R DPI 10 2 x 300 W DPI 15 2 x 500 W DPI 20 2 x 800 W DPI 30 2 x 1 100 W DPI 40 2 x 1 500 W...

Страница 2: ...ications where portability is not a premium requirement DPI incorporates unique features that require some study be fore being applied One of these features is the EFL Extended Feedback Loop remote se...

Страница 3: ...5 4 2 Attaching removing the fancover 5 5 Connecting the amplifier 6 5 1 Familiarisation with the rear panel 6 5 2 Configuartion dipswitch setting 6 5 3 1 Input connections 7 5 3 3 Speaker connection...

Страница 4: ...harmful interference This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions can cause harmful interference There is no guara...

Страница 5: ...s polarisation means of the unit are not defeated Slots and openings in the unit are provided for ventilation To ensure reliable operation and to prevent overheating of the unit these openings must no...

Страница 6: ...IS FOUND NOTIFY THE CARRIE R WHO MADE DELIVE RY DEMAN D AN INSPEC TION AND A SIGNED DAMAG E REPORT THIS PACKAG ING IS MADE FROM FULLY RECYC LABLE MATER IALS KEEP PACKA GING FOR FUTURE USE OR DISPOS E...

Страница 7: ...dule DPI series is standard delivered with the PIM SIM1 analog input module Do not operate the amplifier without the module in place The PIM module can be easilly exchanged for versions with more elab...

Страница 8: ...To avoid cable overheating do not use speaker cables under 1 5 mm2 cross section AWG 15 The use of thicker cables helps to keep power loss down and damping high especially if long distances have to be...

Страница 9: ...rth PE BROWN live L BLUE neutral N Output cabling for dual stereo parallel mono mode Preferred Second option In case the sense inputs are not used leave them unconnected The amplifier will then functi...

Страница 10: ...e speaker protection TCL Temerature Controlled Limiting indicates signal limiting as a result of heat sink over temperature above 85 C This helps to prevent the triggering of the internal thermal shut...

Страница 11: ...s and direct out connectors is connected to chassis ground In a perfect world it would be pos sible to simply connect the sleeves of the signal cables to pin 1 at both ends of the cable This would in...

Страница 12: ...ignal Frequency response 5 Hz 50 kHz 3dB Load impedance 2 16 Ohms Large Signal Bandwidth 35 kHz Rise time 10 s Damping factor 3000 EFL used 1 KHz referred to 8 ohms Voltage gain 36 dB Level controls f...

Страница 13: ...EQUIPMENT MUST BE EARTHED AVIS RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ATTACH TYPE LABELTO THIS LOCATION THIS LABEL CONTAINS IMPORTANT SAFETY INFORMATIONAND...

Страница 14: ...uded by repair or at its option replacement or refund In case of refund the defective or malfunctioning product shall be made available to us free and clear of all lies or other encumbrances The refun...

Страница 15: ...ering NV Q4audio division Tongersesteenweg 190 3800 Sint Truiden Belgium Tel 32 0 11 69 42 59 Fax 32 0 11 69 45 92 Email service Q4audio com Attempts to solve the problem Problem description Be sure t...