background image

WIRE LENGTH TABLE

17
25
40
80

100

VOLTAGE DROP CHART

(W)

VDC

897’

564’

355’

223’

140’

88’

55’

35’

22’

567’

356’

224’

141’

88’

56’

35’

22’

14’

309’

194’

122’

77’

48’

30’

19’

12’

7’

130’

82’

51’

32’

20’

13’

8’

5’

3’

84’

53’

33’

21’

13’

8’

5’

3’

24

10 

AWG

(5.6mm

2

)

12 

AWG

(3.3mm

2

)

14 

AWG

(2.0mm

2

)

16 

AWG

(1.3mm

2

)

18 

AWG

(0.78mm

2

)

20 

AWG

(0.50mm

2

)

22 

AWG

(0.33mm

2

)

24 

AWG

(0.20mm

2

)

26 

AWG

(0.13mm

2

)

Wa�s

*

Distances are based on a 5% Voltage drop max.

● This product must be installed in accordance with the     

   applicable installation code by a person familiar with 
   the construction and operation of the product and the

   hazards involved.

WIRING DIAGRAM

QTM-eLED+DMX

SPECIFICATIONS

12V - 28V DC IN

To connect the driver to a DC power supply unit (PSU), connect the PSU’s positive voltage supply wire to the VDC+ connector and the PSU’s negative 

voltage supply wire to the VDC- connector.

EXT in

You have the possibility to connect an external control device (0-10V control device, 10kΩ potentiometer or show selection switch) to the driver’s Ext in+ 

and Ext in - connector. Configure the driver for use with an external control device over the 3 - button user interface.

DMX in/LedSync out

Use these connectors when the driver is used in a DMX network. For DMX in, connect the network cable’s DMX+, DMX- and DMX shielding wire (the 

orange/white, orange and brown wire in a CAT5 cable) to the DMX in+, DMX in- and DMX in shield connector respectively. For LedSync out, connect the 

network cable’s DMX+, DMX- and DMX shielding wire to the LedSync out+, LedSync out-  and LedSync shield connector respectively. DMX Shield must be 

grounded to Earth Ground at a single point external to power supply

LED groups

Indicates the location of the connectors for your LED groups. R(ed) represents channel 1

, G(reen) represents channel 2, B(lue) represents channel 3 and 

W(hite) represents channel 4. The default group color allocation can be changed over the 3-button user interface.

M

Max | Vdc+

32V | Vdc-

Ext in +

Ext in

DMX in +

DMX in -

DMX in shield

LedSync thru +

LedSync thru -
LedSync shield

TC

1

2

3

Group

Group

Group

Group

LED

 -

4

LINEARdrive 180D

12-28V / 6A Direct voltage controlled LED driver

LED groups

R

R

W

R

B

G

R

R

DMX in shield

DMX in +

DMX in -

Ext in +

Ext in -

{

12 -28VDC IN

-

+

LedSync shield

LedSync thru +

LedSync thru -

1

0.2-1.5 mm

2

0.35 inch

0.5-1.5 mm

2

AWG 20-16

0.35 inch

AWG 24-16

VDC and LED connectors:

Other connectors:

2

© 2020, Q-Tran Inc.  155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777  -  [email protected]  -  www.q-tran.com

Содержание QTM-eLED+DMX

Страница 1: ...AGE LIGHTING SYSTEM QTM eLED DMX COMPLIANT Wear rubber shoes and work on a sturdy wooden or fiberglass ladder This power supply must be installed according to the National Electric Code and local codes and ordinances This power supply is to be installed and serviced only by an licensed electricians This power supply is to be installed so that it is not likely to be contacted by people To avoid a h...

Страница 2: ...ons Suitable for surface or recessed mounting use Primary Voltage Universal 120 277V Wide operating temperature range 4 degF to 122 degF Fits up to 3 100W 24 VDC driver s and DMX decoder module s DMX dimming down to 0 Driver has Class A sound rating Class 2 Output 5 year warranty CSA 239924 Low Voltage Lighting Systems CSA Class 3425 15 and Class 3425 95 CSA Standard C22 2 No 250 0 08 Luminaires A...

Страница 3: ...hese connectors when the driver is used in a DMX network For DMX in connect the network cable s DMX DMX and DMX shielding wire the orange white orange and brown wire in a CAT5 cable to the DMX in DMX in and DMX in shield connector respectively For LedSync out connect the network cable s DMX DMX and DMX shielding wire to the LedSync out LedSync out and LedSync shield connector respectively DMX Shie...

Страница 4: ...SED MOUNT Plenum Door Required Horizontal Vertical SURFACE SPACING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked NOTE Rods not included RECESSED SURFACE ROD SUSPENSION Horizontal ROD SUSPENSION Vertical VERTICAL QTM eLED DMX Housing Mounting Options 3 2020 Q Tran Inc 155 Hill St Milford CT 06460 A...

Страница 5: ...injury or death Disconnect power before servicing or installing CAUTION The device may only be connected and installed by a qualified electrician All applicable regulations legislation and building codes must be observed Incorrect installation of the device can cause irreparable damage to the device and the connected LEDs DMX Shield must be grounded to Earth Ground at a single point external to po...

Страница 6: ...UE M HUE White WHIT M M Intensity 0 255 INT display off 0 1535 0 255 M M M 1 512 Network resolution DMX address 8 BT 16 BT display off ADDR DMX RES NETW M Interpolation OFF VID COLR WHIT GLOW INTERPOL Other features Visual test run Locking the configuration Reset to factory defaults M display off TEST Test R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec displa...

Страница 7: ...Shield DMX DMX M LED Blue Blue White White Green Green Red Red Black 24V W B G R 24V NEU GND HOT GND HOT NEU A B C 6 for interior QTM eLED DMX QTM eLED DMX Wiring Installation 2020 Q Tran Inc 155 Hill St Milford CT 06460 All rights reserved 203 367 8777 sales q tran com www q tran com W B G R 24 W B G R 24 W B G R 24 DMX IN DMXOUT A B C LED LED LED GND DMX DMX Red Blue Green To next power supply ...

Страница 8: ...24 24 24 100 200 300 QTM eLED 60 QTM eLED 120 QTM eLED 180 120 277 120 277 120 277 0 60 0 29 1 20 0 58 1 80 0 87 50 60 50 60 50 60 12 12 12 60 120 180 Q Tran Inc Q TRAN INC MILFORD CT U S A 203 367 8777 WWW Q TRAN COM CLASS 3425 15 3425 95 LOW VOLTAGE LIGHTING SYSTEM Type Ic Recessed Inherently Protected Type IC ENCASTRE PROTECTION INHÉRENTE For Supply Connections Use Wire Rated For At Least 60 C ...