Q-tran QTM-DRIVE Скачать руководство пользователя страница 9

INSTALLATION

  

LED POWER SUPPLY - QTM-DRIVE

© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com 

Specification subject to change. Rev-09-29-20

CSA Requirements

• 

Suitable for indoor use

• 

This power supply must be installed according to the National Electric Code and local codes and ordinances and in 

accordance with applicable installation code by a person familiar with the construction and operation of the product and 

the hazards involved.

• 

Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.

• 

This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.

• 

To avoid a hazard to children, account for all parts and destroy all packaging materials.

• 

DMX shield wire must be grounded to earth ground at a single point external to power supply.

Model

Input Voltage

 (V)

Frequency

Nominal Output

Voltage (VDC)

Nominal Output 

Wattage (W)

Input Current 

(A)

QTM-DRIVE-100

QTM-DRIVE-200

QTM-DRIVE

120/277

120/277

1.05

2.10

50/60

50/60

100

200

QTM-DRIVE-60

QTM-DRIVE-120

120/277

120/277

0.67

1.30

50/60

50/60

60

120

24

24

12

12

Q-Tran, Inc.

Q-TRAN, INC. 

MILFORD, CT U.S.A. 

(203) 367-8777 

WWW.Q-TRAN.COM

CLASS:  

3425 - 15

               

3425 - 95

 

120V-277V

INPUT VOLTAGE

OUTPUT VOLTAGE

DMX

24V

12V

DALI

LOW VOLTAGE 

LIGHTING SYSTEM

This product must be installed in accordance with the applicable 

installation code by a person familiar with the construction and 

operation of the product and the hazards involved.

CONTROL TYPE

 Type IC recessed, inherently protected

    

Type IC ENCASTRE, PROTECTION INHÉRENTE

 Wall mount only

    

INSTALLATION MURALE SEULEMENT

 Suitable for damp locations

    

CONVIENT AUX EMPLACEMENTS HUMIDES

 Not for use with dimmers

    

NE CONVIENT PAS À DES GRADATEURS

● For supply connections use 

wire rated 

   for at least 60ºC. 

 Class 2

CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION 

PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET 

SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.

Содержание QTM-DRIVE

Страница 1: ...ation 1 Size Size Max Load Watts Secondary Voltage 12 24VDC Max Prim Amps 120V Max Prim Amps 277V 60W 1x60W 12VDC 0 60A 0 45A 120W 2x60W 12VDC 2 10A 0 90A 100W 1x100W 24VDC 1 05A 0 45A 200W 2x100W 24VDC 2 10A 0 90A 2 Color WH White Standard BK Black Powder Coat Finish Voltage Drop Chart VDC Watts W 10 AWG 5 6mm2 12 AWG 3 3mm2 14 AWG 3 0mm2 16 AWG 1 3mm2 18 AWG 0 78mm2 20 AWG 0 50mm2 22 AWG 0 33mm2...

Страница 2: ...t for use in lighting products Housing 18 gauge welded steel enclosure 14 5 W x 8 00 H x 4 00 D Door 15 5 W x 9 00 H Knockouts 9 Built in support bracket incorporated to secure housing for surface mounting Performance Power Supply Rated for surface mount or recessed use Fully rated to operate low voltage load at listed wattage No derating required Voltage regulation to 5 or less of rated output vo...

Страница 3: ... per output Output RGB 12V 1 66A per output RGB 24V 1 33A per output Current max 5A common anode ENVIRONMENTAL Ta operating range 40 F 122 F Tc max 185 F Lifetime 50K hours at 122 F MTBF 480 000 hours COMPLIANCE SAFETY Class 2 output Class A sound rating FCC Title 47CFR Part 15 Class B The wiring inside electrical enclosures shall comply with the 600V 105 ºC or higher CSA certified UL 2108 UL 8750...

Страница 4: ... tran com www q tran com Specification subject to change Rev 11 19 20 Lifetime data Life vs Ta 86 140 131 122 113 104 95 30 35 40 45 50 55 60 Ta Life kHours ºF Power factor data Power factor vs Vout at Ta 25 ºC 77 ºF 0 6 0 5 0 4 0 3 0 2 0 1 0 0 70 0 75 0 80 0 85 0 90 0 95 1 00 1 05 Vout V 120V 60Hz 230V 50Hz 277V 60Hz Pf ...

Страница 5: ...ING SURFACE STACKING ROD SUSPENSION 9 5 O C 16 O C 19 O C 9 5 O C 9 5 O C More Units can be stacked More Units can be stacked More Units can be stacked NOTE Rods not included RECESSED SURFACE ROD SUSPENSION Horizontal ROD SUSPENSION Vertical VERTICAL Double Sided Key Hole 1 4 Rod Thru Hole 3 8 Rod Thru Hole NOTE Bracket can also be mounted Top Bottom for Vertical Mounts 0 875 KNOCKOUT 9X FOR 1 2 F...

Страница 6: ...reen Blue Blue White White Black 24V A B DMX Shield DMX PRIMARY SECONDARY DMX DMX OUT DMX IN _ 120 277VAC 50 60Hz DA DA 1 2 LED R G B W 24V R G B W 24 A R G B W 24 B GND HOT NEU LED LED NEU GND HOT GND DMX DMX Red Blue Green To next power supply WARNING Risk of electrical shock May result in serious injury or death Disconnect power before servicing or installing CAUTION The device may only be conn...

Страница 7: ...sual test run Locking the configuration Reset to factory defaults M display off TEST Test R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec R 1 sec G 1 sec B 1 sec W 1 sec RGBW 1 sec display off M LOCK M Lock driver 5 sec NO SOFT HARD M display off RE SET Reset M 5 sec Press menu PRES MENU The colour menu depends on the LED group settings you have selected in step 2 3 Standalone operation Colour or 00 20...

Страница 8: ...llation eldoLED POWERdrive 100 S M _ 120 277VAC 50 60Hz DA DA 1 2 eldoLED POWERdrive 100 S M _ 120 277VAC 50 60Hz DA DA 1 2 Red Red Green Green Blue Blue White White Black 24V M _ 120 277VAC 50 60Hz DA DA 1 2 LED R G B W 24V R G B W 24 A R G B W 24 B DMX OUT DMX IN GND HOT NEU NEU GND HOT A B LED LED GND DMX DMX Red Blue Green To next power supply for interior QTM DRIVE SECONDARY PRIMARY DMX Shiel...

Страница 9: ...ncy Nominal Output Voltage VDC Nominal Output Wattage W Input Current A QTM DRIVE 100 QTM DRIVE 200 QTM DRIVE 120 277 120 277 1 05 2 10 50 60 50 60 100 200 QTM DRIVE 60 QTM DRIVE 120 120 277 120 277 0 67 1 30 50 60 50 60 60 120 24 24 12 12 Q Tran Inc Q TRAN INC MILFORD CT U S A 203 367 8777 WWW Q TRAN COM CLASS 3425 15 3425 95 120V 277V INPUT VOLTAGE OUTPUT VOLTAGE DMX 24V 12V DALI LOW VOLTAGE LIG...