Q-Pumps QIS Series Скачать руководство пользователя страница 15

 

 

 

15 

QIS SERIES-M

03

 

 

OPERATION AND MAINTENANCE MANUAL 

QIS SERIES 

Centrifugal Pump 

the stationary face; the static face has a gutter in the middle between both O-rings, do not block 
this, and remember that you can use water or dishes soap to lubricate or glue O-rings and gaskets 
to the metal elements to ease assembly. Place the stationary face into the backplate seal housing, 
the square shape in both parts must be aligned.  Push  until the seal surface fully seats on the 
housing.  Figure 

K

 

Figure 

K

 

 
Place and fix the backplate already with the stationary seal installed into the adapter as in step 

3b

.  

Use torque value to fix the backplate of 

6 ft.lb

 

for all the models.  Be carefull not to hit the seal 

with the stubshaft end. 
 

4c.  Internal rotary seal sub-assembly, single and double mechanical seal.

  Assembly the internal 

rotary face (

6B

), the rotary seal O-ring (

6I

), internal spring (

6E

) and rotary holder O-ring (

6H

) into the 

rotary holder (

6A

).  First place the O-ring (

6I

) into the groove on the rotary holder.  Then place the 

spring inside the rotary holder taking care the spring tip fits the notch in the rotary holder.  Insert 
the  internal  rotary face into the rotary holder.  The second spring tip must fit the notch  in the 
internal rotary face, then compress.  Finally place the rotary holder O-ring (

6H

) in the groove on 

the front of the holder.  Figure 

L. 

 

 

Figure 

L

 

7

6K

6C

6J

6H

6A

6E

6I

6B

Gutter 

O-ring 

6K

 

O-ring 

6J

 

O-ring 

6I

 

O-ring 

6H

 

AS

S

E

MBL

Y

 

Содержание QIS Series

Страница 1: ...02 11 QIS SERIES OPERATION AND MAINTENANCE MANUAL INTERNAL BALANCED MECANICHAL SEAL CENTRIFUGAL PUMP en q pumps com s u p p o r t q p u m p s c o m...

Страница 2: ...practical advices for the maintenance and operation of the equipment ABOUT THIS MANUAL 3 Q Pumps S A de C V Warranty 3 SAFETY 4 IMPORTANT SAFETY INFORMATION 4 INSTALATION 5 DESCRIPTION 5 INSTALLATION...

Страница 3: ...ormal wear include but are not limited to standard rotors wear casing mechanical seals gears and bearings wear Accidents operating errors or improper maintenance are not covered by the warranty Q Pump...

Страница 4: ...ed within these instructions to avoid serious injury and or possible damage to equipment Safety labels are placed on every pump DO NOT remove any labeling on any Q Pumps product Replace any label that...

Страница 5: ...nical seal single or double assures long seal life The drive motor is mounted on a frame having adjustable legs providing simple installation and leveling INSTALLATION GUIDELINES UNPACKING EQUIPMENT C...

Страница 6: ...SEMBLY PRELIMINARIES Before beginning the assembly procedure identify every element that is going to be installed you can use the exploded view and part list shown in pages 7 and 8 During the assembly...

Страница 7: ...QIS SERIES Centrifugal Pump QIS GENERAL DIAGRAM GENERAL DIAGRAM 1 2 3 4 5 6 7 9 8 10 12 13 14 18A 18B 17 21 22 19 20 16 209 207 209A 209B 15 6H 6A 6G 6E 6I 6B 6J 6C 6K 6D 6L 6F 6H 6A 6G 6E 6I 6B 6J 6C...

Страница 8: ...rotary face 1 18A Adapter hexagonal screw 4 6C Static face 1 18B Adapter hexagonal nut 4 6D External rotary face 1 19 Washer 4 6E Internal rotary spring 1 20 Casing hexagonal screw 4 6F External rotar...

Страница 9: ...ned below 1 LEG BRACKET ASSEMBLIES The leg bracket assemblies are optional They allow to level the pumps adjusting the legs vertically The size of the brackets 209 and legs 207 depend on the NEMA or I...

Страница 10: ...ue values recommended in chart 1 Table 1 Torque values for tightening the adapter screws Torque ft lb Models NEMA Models IEC 55 Frame 18 to 25 Frame 110 to 160 70 Frame 28 Frame 180 110 Frame 32 to 36...

Страница 11: ...b shaft collar 13 with the corresponding Allen screws 14 loosely on the stub shaft 10 and place it on the motor shaft it must slide in and out without problem Figure D Figure D 3b Place and fix the ba...

Страница 12: ...ket 4 on it then place the impeller 5 in the stub shaft and tighten with the impeller nut compressing the assembly Figure F Figure F Use a 5 8 hexagonal socket for models 114 and 214 and a 7 8 hexagon...

Страница 13: ...th the shim between them and proceed to tighten the screw or screws on the shaft collar Use the torque values for tightening the collar screws indicated in the chart 2 Figure H Figure H Table 2 Torque...

Страница 14: ...nsert the O ring 6L into the external rotary face 6D then locate the external spring 6F inside the external rotary face Be sure the spring tip fits in the notch on the rotary face Now slide the subass...

Страница 15: ...to fix the backplate of 6 ft lb for all the models Be carefull not to hit the seal with the stubshaft end 4c Internal rotary seal sub assembly single and double mechanical seal Assembly the internal...

Страница 16: ...ly into the stub shaft The seal will contact the stationary seal face placed previously in the backplate step 4a Push to compress the assembly and then insert the impeller key put the impeller and tig...

Страница 17: ...SEMBLING THE CASING 5a Once the mechanical seal has been installed and the impeller impeller nut assembly has been tightened use the four hexagonal screws 20 and washers 19 to fix the casing Place the...

Страница 18: ...ety reasons not to operate the equipment if it is not placed in the adapter Figure Q Figure Q 5c Your assembly is complete Figure R Figure R Notes 1 Before starting the pump check that the motor turns...

Страница 19: ...move obstruction and open valves 2 INSUFICIENT FLOW a Motor speed too low b Incorrect rotation direction c Obstruction in discharge piping or closed valves d Impeller damaged a Check electric connecti...

Страница 20: ...mp Q Pumps Inc 1220 Bammel Road Houston TX 77073 Call 832 957 37 06 832 205 2885 Q Pumps S A de C V Acceso A 103 Fracc Industrial Jurica Quer taro Qro M xico 76130 Call 52 442 103 31 00 For Technical...

Отзывы: