Operation and Maintenance Manual 

QC Series  Centrifugal Pump

QC-M02

HOW TO INSTALL THE PIPING

GENERAL

This section provides some do’s and do not’s of piping which will aid in obtaining the maximum 

efficiency and service from your pump. Piping should be independently supported at both the 

suction inlet and discharge outlet. Care should be taken that piping is properly aligned and does 

not put any strain on the pump casing. The piping should have as few bends as possible.

SUCTION PIPING

The suction piping should be short and follow a direct route with a minimum number of elbows 

and fittings. Elbows should be located as far as possible from the suction inlet to prevent head 

loss due to increased friction. Excessive friction losses in the suction line could result in pump 

cavitation, causing poor performance, noise, vibration, damage to equipment and possible 

damage to fluid.

Whenever possible the diameter of the piping at the suction inlet should be increased in size, an 

eccentric tapered reducer should be used instead of a concentric tapered reducer to prevent 

air pockets from forming and impairing pump efficiency. In turn, the eccentric reducer may be 

placed at the inlet of the pump and should be positioned so the straight side is up. A horizontal 

suction pipe must have a gradual rise to the pump. A high point in the suction line will form an 

air pocket and prevent proper pump operation. All joints in the suction line should be air tight, to 

prevent air leakage which can reduce pump capacity and efficiency.

DISCHARGE PIPING

Position of the pump discharge is preferably either vertical or top horizontal. The discharge piping 

should be short and direct with a minimum number of elbows and fittings. Elbows should not be 

used at the discharge outlet, as the friction encountered would be increased, resulting in head 

loss. However, use of a large discharge pipe than recommended may reduce the total pump 

head, but increase the pump volume, which can cause pump vibration due to overload. Use 

of a discharge pipe smaller than the pump discharge outlet increases the total pump head but 

decreases the volume. If a reducer is required on the outlet port of the pump and the discharge 

is vertical a concentric reducer should be used. If the 

discharge is horizontal an ec centric reducer should be 

used and should be positioned so the straight side is 

down.

LOCATING VALVES

In suction lift applications where the lift is not very 

high, it may be desirable to install a foot valve, to 

facilitate priming, and to prevent draining off of the 

liquid back to the source. A throttling valve should 

be installed in the discharge piping to provide control 

pump flow rate and prevent motor overload.

 

 

IN

ST

ALL

ATIO

N

Содержание QC Series

Страница 1: ...Maintenance service and installation manual Q C S e r i e s C e n t r i f u g a l P u m p www qpumps com QC M02 support qpumps com...

Страница 2: ...stub shaft 11 Assembling and installing the mechanical seal 12 Kit plus assembly 17 Industrial T21 seal assembly IC series 18 General assembly inspection 19 Impeller retention 19 Casing assembly 20 B...

Страница 3: ...include but are not limited to standard rotors wear casing mechanical seals gears and bearings wear Accidents operating errors or improper maintenance are not covered by the warranty Q Pumps assumes...

Страница 4: ...used within these instructions to avoid serious injury and or possible damage to equipment CODE 136530002 Guard warning Safety labels are placed on every pump DO NOT remove any labeling on any Q Pump...

Страница 5: ...e motor is mounted on a frame having adjustable legs providing simple installation and leveling INSTALLATION GUIDELINES UNPACKING EQUIPMENT Check the contents and all wrapping when unpacking your equi...

Страница 6: ...rizontal suction pipe must have a gradual rise to the pump A high point in the suction line will form an air pocket and prevent proper pump operation All joints in the suction line should be air tight...

Страница 7: ...mp model This assembly works exactly the same as a standard assembly from the QC series QC PLUS QC SERIES The QC plus series have been development to facilitate the assembly of the QC series pumps off...

Страница 8: ...8 Operation and Maintenance Manual QC Series Centrifugal Pump QC M02 EXPLODED ASSEMBLY...

Страница 9: ...plus Bolt drive collar 1 2 1 1 1 1 2 1 2 1 1 4 4 1 1 1 4 2 4 4 1 1 1 1 1 1 1 1 11B 11F 17 17A 17B 17C 80 80B 80G 80H 80J 80M 83C 83D 83E 11F 11P 95 1 2 6E 24 92A 71 71A 71B 75 90 131 131A 132 M Backpl...

Страница 10: ...the adapter pins using the two backplate pins 11F located on the backplate Depending upon the pump model and seal type some backplates do not have pins for reasons of design The adapter comes with a p...

Страница 11: ...distance of 0 070 in from the face of the backplate and tighten the set screws in order to secure the stub shaft STUB SHAFT PLUS Next place the backplate onto the adapter 71 and turn it in a counter...

Страница 12: ...flipping the seal is sufficient to continue using it The E seal is a double balanced seal cooled by water This seal is composed of a stuffing box which is filled with fluid normally water to cool the...

Страница 13: ...the leak falls upon the seal seat of the carbon lubricating the seal against the backplate IMPORTANT It is necessary to disassemble some of the pump parts for cleaning and sterilizing For those Q Pum...

Страница 14: ...ng Once the backplate is set onto the adapter push the drive collar against the backplate to compress the spring Tighten the set screws to set the seal when the spring no further can move The efficien...

Страница 15: ...eal o ring and cup onto the stub shaft using the E drive collar 80J as a support for the o ring The seal seat of the carbon should be able to touch the follower 17 Slide the drive collar onto the stub...

Страница 16: ...s on the stuffing box point upward and with a 45 inclination from the horizontal plane as shown in Figure J The water should enter through one connection and leave through another moving through the s...

Страница 17: ...peller gasket 91B impeller plus 2P and impeller nut 24D IMPORTANT In some cases the front and back gaskets are interchangeable only models 218 328 and 4410 The Kit plus is compatible with D DG F and E...

Страница 18: ...adapter has been mounted to the motor and the impeller has been placed at a distance of 0 070 in from the backplate If the stub shaft has not yet been assembled please return to section 3 before conti...

Страница 19: ...parts impeller 2 retainer 24 and standard stub shaft 6E Place the retainer into the drilled hole atop the stub shaft so that it is completely receded When you have placed the impeller at the back mak...

Страница 20: ...on Take the clamp assembly 75 and place it around the casing Tighten the clamp to close the casing so that it is level around the perimeter A rubber mallet may be helpful when installing the casing 10...

Страница 21: ...EXCESSIVE POWER CONSUMPTION a Motor speed too high b Impeller damaged c Motor shaft is bended or worn 4 EXCESSIVE NOISE a Magnetic problem with motor b Motor bearings damaged c Foreign particles in im...

Страница 22: ...3 Fraccionamiento Industrial Jurica Quer taro Qro M xico C P 76130 Call 52 442 218 4570 218 7400 Fax 52 442 218 4577 Operation and Maintenance Manual Centrifugal pump QC Series support qpumps com www...

Отзывы: