background image

20

21

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS GMBH – EN

20

Q CELLS solar modules are known for a long operating 
life and minimal maintenance effort and expense. Dirt 
and grime are usually washed away by rain. If the module 
is fully or partially shaded by dirt or debris (e.g., plants, 

bird droppings), it needs to be cleaned to prevent a loss 

of performance.

Maintenance

 

Ä

The system should be inspected by an installer annually 
to check the following:

• 

all system components sit securely and are corrosion 
free.

• 

the connection is secure and all electrical components 
are clean and undamaged.

Cleaning

WARNING!  
Risk of injury due to hot and  
live modules!

 

Ä

Only clean modules that have cooled down.

 

Ä

Do not carry or wear any electrically conductive parts.

WARNING!  
Risk of falling due to unsecured  
access!

 

Ä

Never access the installation area alone or without 
taking adequate security precautions.

 

Ä

Please commission a trade specialist.

Clean the modules as follows:

NOTE!  
Module surface damage may occur! 

 

Ä

Remove snow and ice carefully without force (e.g. with 

a very soft broom).

 

Ä

Do not scratch off dirt.

 

Ä

Rinse dirt (dust, leaves, etc.) off with lukewarm water or 

use an alcohol based glass cleaner. Do not use abrasive 
detergents or tensides. 

 

Ä

Use a soft cellulose cloth (kitchen roll) or sponge to 
carefully wipe off stubborn dirt. Do not use micro fleece 

wool or cotton cloths.

Isopropyl alcohol (IPA) can be used selectively to remove 

stubborn dirt and stains within one hour after emergence.

 

Ä

Please follow the safety guidelines provided by the IPA 
manufacturer. 

 

Ä

Do not let IPA run down between the module and the 
frame or into the module edges.

 

Ä

Free the substructure from any dirt and 

debris (leaves, bird nests, etc.).

 

Ä

Remove dirt with lukewarm water or 
alcohol based glass cleaner, a broom, or 
a soft cloth.

 

Ä

Do not use tensides, scrapers, or any 
high-pressure water cleaning equipment.

NOTE

! Module damage may occur!

 

Ä

Do not clean modules with water if there 
is a risk of frost.

MAINTENANCE AND CLEANING 

Содержание Q.PRO-G4.X

Страница 1: ...Valid for Africa Asia Europe Latin America South America Q PRO G4 X Q PRO EC G4 X Q PRO BFR G4 X Q PLUS BFR G4 X INSTALLATION AND OPERATION MANUAL...

Страница 2: ...possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations In particular the installer a...

Страница 3: ...xt of accepted guarantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for any other sys tem components that may be part of t...

Страница 4: ...expansion and contraction due to temperature fluctuations Ensure that no mechanical stresses e g caused by vibrations twisting or expansion are generated on the module Ensure that the clamps and the m...

Страница 5: ...of module and middle of the clamp Describes the maximum module surface load vertical to the module surface regarding safety factors e g EUROCODE For this purpose the load value determined by load tes...

Страница 6: ...y module defects ground leaks or defective insulation Ensure that the maximum reverse current load capacity indicated in the data sheet is met In order to limit reverse currents that may occur we reco...

Страница 7: ...modules NOTE Module damage may occur Do not install modules near flammable gas vapors Do not install modules in close proximity to air conditioning systems 3 1 Safety and transport 3 INSTALLATION DAN...

Страница 8: ...can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit voltage is active even at low levels of solar...

Страница 9: ...ropriate and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Use solar cables for th...

Страница 10: ...NECTION Protective Grounding The modules must be grounded in accordance with the local statutory regulations Functional grounding When using an installation tilt of 5 a functional grounding at the neg...

Страница 11: ...area alone or without taking adequate security precautions Please commission a trade specialist Clean the modules as follows NOTE Module surface damage may occur Remove snow and ice carefully without...

Страница 12: ...Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installa...