INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.POWER-G5 / L-G5 • Q.PRIME-G5 / L-G5 – EN
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.POWER-G5 / L-G5 • Q.PRIME-G5 / L-G5 – EN
Installation Site
Please note the following guidelines that apply to the
installation site:
•
The modules have been tested according to IEC 61215
for operation in a temperate climate.
•
Solar modules are not explosion-proof and are not suitable
for use in explosive environments.
Ä
Do not operate solar modules near highly flammable gas
and vapors (e.g. gas tanks, gas stations).
Ä
Do not install modules in enclosed space.
Ä
Do not install modules in locations where they may be
submerged in water for lengthy periods (e.g. floodplains).
Ä
Do not use modules as a substitute for the normal roofing
(e.g. modules are not rainproof).
Ä
Do not install modules in close proximity to air conditioning
systems
Ä
Do not install modules above 4000 m (13.120 ft) altitude
above sea level.
Ä
Do not bring any chemical substance (e.g. oil, solvent etc.)
into contact with any part of the panel. Only substances,
which are released by Q CELLS, are allowed to be used
during installation, operation and maintenance.
Ä
If the place of installation is very close to some special
environments including, but are not limit to seaside,
desert, high altitude, chemical plant. Please inform us
before you install to make sure if our warranty will be
covered or not.
The solar modules are designed for the following applications:
•
Operating temperatures from –40 °C to +85 °C.
•
Wind loads up to max. 2,400 Pa and snow loads
up to max. 5,400 Pa (Test-load in accordance with
IEC 61215, see chapter 2.3 mounting options).
•
Installation using a mounting frame for solar modules.
Prevention of Shadowing Effects
Optimal solar irradiation leads to maximum energy output:
Ä
For this reason, install the modules so that they face
the sun.
Ä
Avoid shadowing (due to objects such as buildings,
chimneys or trees).
Ä
Avoid partial shading (for example through overhead
lines, dirt, snow).
Mounting Frame Requirements
The Modules shall be installed and operated on mounting
frames that comply with any applicable laws and stipulations
as well as with the following:
•
Conform to the necessary structural requirements.
•
Compliant with local snow and wind loads.
•
Properly fastened to the ground, the roof, or the façade.
•
Forces acting on the module are relayed to the mounting
substructure.
•
Ensures sufficient rear ventilation of the module.
•
Guarantees long-term stability.
•
Avoid the usage of different metals to prevent contact
corrosions.
•
Allows for stress-free expansion and contraction due to
temperature fluctuations.
Ä
Ensure that no mechanical stresses (e.g., caused by
vibrations, twisting, or expansion) are generated on
the module.
Ä
Ensure that the clamps and the mounting frame are
compatible.
Clamp System Requirements
Use customary clamps that satisfy the following requirements:
•
Clamp width:
≥
38 mm.
•
Clamp height compliant with a 35 mm frame height.
•
Clamp depth: 11-13 mm.
•
Recommended tightening torque 5 -10 Nm.
•
Clamps are not in contact with the front glass.
•
Clamps do not deform the frame.
•
Clamps that satisfy the structural requirements of the
installation site.
•
Long-term stable clamps that securely affix the module
to the mounting frame.
Module Orientation Requirements
•
Vertical or horizontal installation is permitted.
Ä
Ensure that rain and melting snow can run off freely.
No water accumulation.
Ä
Ensure that the drainage holes in the frame are not
covered. No sealing.
Ä
Maintain the permissible angle of
inclination.
•
Minimum angle of inclination: 3°
•
Inclination angles above 75° may be
limited by local regulations
Ä
≥
20°: self-cleaning effect
Ä
Follow the directions for installation
angles < 5° (“Grounding”, p. 20)
75°
3°
2.2 Requirements
2 PLANNING
Fig. 2:
External dimensions (in mm) and components for Q.PRIME-G5.1, Q.POWER-G5.1
EN
Junction bo×
Label
1670 mm
4 ×
Mounting slots
(DETAIL A)
Cable with
connectors
Frame
1000 mm
8 × Drainage holes
4 × Grounding points ø 4.5 mm
≥ 1000 mm
980 mm
DETAIL A
16 mm
8.5 mm
24.5 mm
951 mm
345 mm
4 × Drainage holes
32 mm
Additional information can be found in the currently valid data sheets available at www.q-cells.com.
PRODUCT LINE
Q.PRIME-G5.1
Q.POWER-G5.1
Type
Monocrystalline
Polycrystalline
Length
1670 mm
1670 mm
Width
1000 mm
1000 mm
Frame height
32 mm
32 mm
Weight
18.5 kg
18.5 kg
Max. system voltage V
SYS
[V]
1000 (IEC) /
1500 (IEC)
1000 (IEC) /
1500 (IEC)
Max. fuse rating [A]
20
20
Permissible
temperature range
–40 °C to +85 °C
Junction box protection class
IP67 or IP68, with bypass diodes
IP67 or IP68, with bypass diodes
Connector protection class
IP68
IP68
Fire protection class
C
C
Snow load
[Pa
1
]
5400
5400
Wind load
[Pa
1
]
4000
4000
Certificates
CE-compliant; IEC 61515 (Ed.2) see page 8; IEC 61730 (Ed.1)
Application Class A
1
Test-load in accordance with IEC 61215
32 mm
32.8 mm
12 mm
17.5 mm
24.55 mm
5 mm
8.5 mm
G5.1