INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO L-G6.3 / BFG AND L-G6.3 / BGT – Q CELLS
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO L-G6.3 / BFG AND L-G6.3 / BGT– Q CELLS
17
16
0.20 in (5 mm)
0
in
(0
mm)
NA
Option 1:
Ä
Fasten the module with 4 clamps in the specified
clamping range, see Fig. 2, p. 8.
Ä
Tighten clamps according to manufacturer’s
instructions.
Ä
Maintain an interval of at least 0.20 in (5 mm)
between two modules along the short side.
NOTE! Module damage may occur!
Ä
Do not subject modules to mechanical tension.
Max. torsion 0.12 in/ft (10 mm/m).
Option 2:
Ä
Install the module at the 4 mounting points,
see Fig. 2, p. 8.
Ä
Tighten screws according to manufacturer’s
instructions.
Option 3:
Ä
Install the module using mounting profiles,
see Fig. 2, p. 8.
3
INSTALLATION
3.3 MODULE INSTALLATION
DANGER!
Risk of fatal injury due to electric shock!
When disconnecting an electric circuit carrying direct current,
electric arcs can occur that may result in life-threatening injuries.
Ä
Do NOT unplug the cable when under load.
Ä
Do NOT connect any exposed cable ends.
Ä
Electrical work may only be performed by qualified and skilled
personnel (see page 3).
A solar module generates electrical current and voltage even
at a low intensity of illumination. Sparks and electric arcs may
result from the separation of a closed circuit. These can result
in life-threatening injuries. The danger increases when several
modules are connected in series.
Ä
Please be aware of that the entire open circuit voltage is active
even at low levels of solar irradiation.
Ä
Please follow the valid national regulations and safety guidelines
for the installation of electrical devices and systems.
Ä
Please make sure to take all necessary safety precautions. With
module or phase voltages of more than 120 V, the safety extra-
low voltage range is exceeded.
Ä
Carry out work on the inverter and the wiring with extreme
caution.
Ä
Ensure that the modules are disconnected at the inverter prior
to separation.
Ä
Be sure to observe the time intervals specified by the inverter
manufacturer after switching off the inverter.
Ä
Make sure that the plugs can not be connected unintentionally.
Ä
Before working on the contacts, check them for safety extra-
low voltage.
DANGER! Risk of fatal injury due to electric shock!
Ä
Never open the junction box.
Ä
Do not remove bypass diodes.
DANGER! Risk of fatal injury due to electric shock!
Ä
Never touch live contacts with bare hands.
Ä
Cover connectors by suitable protective caps until
installation.
DANGER! Risk of fatal injury due to electric shock!
Ä
Insulate any exposed cable ends.
Ä
Only connect cables with plugs.
DANGER! Risk of fatal injury due to electric shock!
Ä
Only use dry, insulated tools for electrical work.
4 ELECTRICAL CONNECTION
4.1 SAFETY