4
5
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO-G10.X – Q CELLS
INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO-G10.X – Q CELLS
Validity
These instructions are only valid for crystalline solar modules from
the company Q CELLS as specified at chapter „2.1 Technical
Specifications“. Q CELLS assumes no liability for damage resulting
from failure to observe these instructions.
Ä
Please observe the wiring and dimensioning of the system.
Ä
The installer of the system is responsible for compliance with all
necessary safety regulations during set-up and installation.
Q CELLS assumes no liability on the basis of these instructions.
Q CELLS is only liable in the context of contractual agreements
or in the context of accepted guarantees. Q CELLS accepts no
other responsibility for the functionality and safety of the modules.
Ä
Please observe the instructions for any other system compo-
nents that may be part of the complete solar power system.
It may be necessary to carry out a structural analysis for the
entire project.
Additional information for the Operator
Ä
Please keep this manual for the entire life of the solar power
system.
Ä
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Ä
Please be sure to contact the relevant local authorities and
energy providers regarding regulations and permit requirements
prior to installation of the solar power system. Your financial
success depends on the fulfillment of these requirements.
Other applicable documents
In addition to this Manual following technical information are
relevant:
DOCUMENT TYPE
Product data sheet
Packaging and transport information
External dimensions and components for
Q.PEAK DUO-G10, Q.PEAK DUO-G10+, Q.PEAK DUO-G10.a,
Q.PEAK DUO-G10.a+, Q.PEAK DUO-G10.4, Q.PEAK DUO-G10.4+,
Q.PEAK DUO BLK-G10, Q.PEAK DUO BLK-G10+,
Q.PEAK DUO BLK-G10.a, Q.PEAK DUO BLK-G10.a+,
Q.PEAK DUO BLK-G10.4 and Q.PEAK DUO BLK-G10.4+
DE
DETAIL A
16 mm
8,5 mm
21,25 mm
980 mm
1717 mm
4 × Befestigungspunkte
(DETAIL A)
Rahmen
1045 mm
32 mm
8 ×
Entwässerungslöcher
368,5 mm
4 × Erdungsbohrung ø 4,5 mm
Label
≥
1150 mm
≥
1150 mm
1002,5 mm
For additional information see the relevant datasheet of the module provided at www.q-cells.com.
PRODUCT LINE
Q.PEAK DUO-G10
Q.PEAK DUO-G10+
Q.PEAK DUO-G10.a
Q.PEAK DUO-G10.a+
Q.PEAK DUO BLK-G10
Q.PEAK DUO BLK-G10+
Q.PEAK DUO BLK-G10.a
Q.PEAK DUO BLK-G10.a+
Q.PEAK DUO-G10.4
Q.PEAK DUO-G10.4+
Q.PEAK DUO BLK-G10.4
Q.PEAK DUO BLK-G10.4+
Type
Q.ANTUM DUO Z
Q.ANTUM DUO Z
Monocrystalline PERC
Length
1717 mm
1717 mm
1717 mm
Width
1045 mm
1045 mm
1045 mm
Frame height
32 mm
32 mm
32 mm
Area
1.79 m²
1.79 m²
1.79 m²
Weight
19.9 kg
19.9 kg
19.9 kg
Max. system voltage V
SYS
1000 V
1000 V
1000 V
Max. reverse current
20 A
20 A
20 A
Permissible
temperature range
–40 °C to +85 °C (–40 °F to +185 °F)
Junction box
protection class
IP67 with bypass diode
Connector protection class
IP68
Fire rating based on ANSI / UL
61730
C / Type 2
C / Type 2
C / Type 2
Max. test load Push / Pull
1
5,400 Pa / 4,000 Pa
5,400 Pa / 4,000 Pa
5,400 Pa / 4,000 Pa
Max. design load Push / Pull
1
3,600 Pa / 2,660 Pa
3,600 Pa / 2,660 Pa
3,600 Pa / 2,660 Pa
Certificates
CE-compliant; IEC 61215:2016; IEC 61730:2016; PV module classification: Class II;
UL 61730; QCPV
1
Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section „2.3 Mounting Options“)
1 INTRODUCTION
2 PLANNING
2.1 TECHNICAL SPECIFICATIONS